期刊文献+

絮凝程度变化对新闻纸系统留着、滤水及成纸匀度的影响 被引量:1

Effect of Flocculation Degree on the Retention,Drainage and Formation of Newsprint System
在线阅读 下载PDF
导出
摘要 本文通过采用基于透光脉动原理自制的PDA(Photometric Dispersion Analyzer)系统,研究了常用的助留剂,如阳离子聚丙烯酰胺,在新闻纸浆料悬浮液中所形成的絮团絮凝大小与新闻纸的留着、滤水及与新闻纸手抄纸匀度的关系。 In this paper, the flocculate size of several retention aids, such as polyacrylamide, formed in suspension of newspaper pulp was investigated and its effects on the retention, drainage and formation of newsprint furnish were also studied using self-made Photometric Dispersion Analyzer, a transmitted light fluctuation-based PDA system.
出处 《造纸科学与技术》 北大核心 2009年第3期33-35,70,共4页 Paper Science & Technology
基金 国家自然科学基金(20776054) 广东省自然科学基金博士启动项目 教育部高校博士点基金新教师课题(200805611104) 广东省高等学校自然科学研究重点项目(06Z002)资助
关键词 新闻纸 絮凝 留着 滤水 匀度 newsprint retention drainage flocculation formation
  • 相关文献

参考文献9

  • 1宋德龙,邝仕均,张睿玲,陈守勤,林一亭,陈德强.低定量新闻纸工艺技术的研究[J].中国造纸,2002,21(5):1-4. 被引量:4
  • 2Dunham, A.J. , Tubergen, K. B. , Govoni, S.T. et al. Effects of dissolved and colloidal substances on flocculation of mechanical pulps[J]. Journal of Pulp and Paper Science, 2000,26(3 ) :95 - 101.
  • 3Shanshan Chou. Application of optical monitor to evaluate the coagulation of pulp wastewater[J]. Water Science and Technology, 1998,37(12) :111 - 119.
  • 4Chihpin Huang. Automatic control for chemical dosing in laboratory-scale coagulation process by using an optical monitor[J]. Water Research, 1996,30 ( 8 ) : 1924 - 1929.
  • 5Ovenden Cherie, Xiao Huining. Flecculation behaviour and mechanisms of cationic inorganic microparticle/polymer systems [ J ]. Colloids and Surfaces A: Physicochemical and Engineering Aspects, 2002,197(1):225 - 234.
  • 6Xiao Huining, Cezar, Norlito. Organo-modifled cationic silica nanoparticles/anionic polymer as flocculants [ J ]. Journal of Colloid and Interface Science, 2003,267 (2) : 343 - 351.
  • 7Burgess M. S. , Curley J. E. , Wiseman N.. On-line optical determination of floc size. PartⅠ: Principles and techniques[J]. Journal of Pulp and Paper Science, 2002,28(10) : 63 -65.
  • 8Burgess, Michael S. , Curley, J. E. , Wiseman, N.. On-line optical determination of floc size-Part Ⅱ: The effect of shear on floe size[J]. Journal of Pulp and Paper Science, 2002,28(10) :323 - 326.
  • 9Burgess M. S. , Phipps J. S. , Xiao. Floceulation of PCC induced by polymcr/microparticle systems: Floe characteristics [ J ]. Nordic Pulp and Paper Research Journal, 2000, 15 (5) : 572 - 578.

二级参考文献8