摘要
在电力系统事故恢复过程中,火电机组的恢复次序对电力系统的恢复有重大影响。本文在分析了影响火电机组恢复及出力的各种因素后,将定性与定量分析方法相结合,建立了火电机组恢复的层次模型,最后给出了算例。
The priority sequence of unit restoration exertsmajor influence on the success of restoration of the whole system. This paper analyzes various factors that affect therestoration of thermal units and their load-up, and an analytical hierarchy process model has been built by combining qualitative and quantitative analyses. The result of calculation indicates that the model is correct and can be used.
出处
《电网技术》
EI
CSCD
北大核心
1997年第6期48-51,54,共5页
Power System Technology
关键词
层次分析法
电力系统
故障
火电机组
恢复运行
Power system restoration
Sequence of unit restoration
Analytical hierarchy process