摘要
实验研究了同心气动喷雾器与不同结构的雾室组合产生的样品气溶胶的性质,包括雾滴粒度分布、传输效率及分析物粒子在等离子体中的滞留时间等。在此基础上,对本文提出的HW雾室结构及其性能进行了实验比较。
Aerosol properties produced by combination of a pneumatic nebulizer with different kind of spray chambers, including aerosol transport efficiency, aerosol droplet size distribution, and resistance time of analyte particles, were investigated. The construction and analytical performance of HW spray chamber proposed were given.