本文结合我们多年的科研工作,介绍了在微波热疗机中测控温的重要性及其难点,比较了多种测控温方案及其临床应用特点,并论述了利用有限的温度测量信号计算热疗温场分布的方法和应用自适应广义预测控制的优越性。
The importance and difficulty of the temperature measurement and control in microwave hyperthermia instruments are discussed in combination with our scientific research work for many years.Plans of the temperature measurement and control,and the characteristics of the clinical application are compared.Finally the method of caculating the temperature distribution with few measurement signals and the advantages of using the adaptive generalized predictive control (GPC) are expounded.