摘要 线损率是考核供电企业的一项综合性经济指标,节能降损是我国部署"节能减排"方针的一项重要而又紧迫的任务。在借鉴吉林、江苏等省的先进线损管理经验基础上,分析了广东电网当前线损"四分"管理工作的现状和存在的问题,并有针对性地提出了一些供参考的意见。 Line loss rate is a comprehensive economic indicator for assessing power supply enterprise, and the line-loss reduction becomes an important and urgent task to accord with the energy-saving and loss reduction policy of China. Based on the advanced line loss management experience of some provinces such as Jilin and Jiangsu, this paper analyzes the current status and problems of Four-ins line loss management (i. e. line loss management in voltages, regions, lines and transformer- supplied ranges) of Guangdong power grid, and gives some counter measures to resolve the problcms.
出处 《广东电力》 2007年第11期14-17,共4页 Guangdong Electric Power
关键词 线损管理 电网结构 无功补偿 降损措施 line loss management power grid structure reactive power compensation line-loss reduction measure