乌拉山发电厂3号锅炉空气分级燃烧改造及运行试验 被引量:3

RETROFIT FOR AIR STAGED BURNING AND OPERATION TEST OF BOILER NO.3 IN WULASHAN POWER PLANT
在线阅读 下载PDF
导出
摘要 采用降低总过量空气系数、增加燃尽风(分级二次风)份额和动压头、适当增加含粉三次风等方法,实现了乌拉山发电厂3号锅炉燃料分级燃烧改造。对改造后锅炉进行了运行试验,结果表明,脱氮效果明显,锅炉效率也有提高。 Adopting methods, such as lowering the total excess air ratio, increasing the share of burn up air (staged secondary air) and the kinetic pressure, as well as suitably increasing the tertiary air containing pulverized coal, etc. , retrofit of fuel staged burning for boiler no. 3 in Wulashan Power Plant has been realized, and operation test of the retrofitted boiler being carried out. Results show that the effectiveness of denitrification is remarkable, and the boiler efficiency being also enhanced.
作者 佐双吉
机构地区 内蒙古工业大学
出处 《热力发电》 CAS 北大核心 2007年第4期61-64,共4页 Thermal Power Generation
关键词 锅炉 燃烧器 一次风 二次风 过量空气系数 空气分级燃烧 运行试验 boiler burner primary air secondary air excess air ratio air staged burning operation test