叙述了扬州二电厂一期脱硫改造过程中烟囱配套的防腐方案,防腐材料选用过程,以及施工过程中的工艺要求,对电站现役机组进行湿法脱硫改造条件下烟囱的防腐技术方案选用和施工有一定的借鉴意义。
The stack anticorrosion program of wet flue gas desulfurization remodification project in YangZhou second thermal power plant was narrated. The anticorrosion material selection as well as the technological requirement of construction process were analyzed, which provided significant reference for other power plants stack anticorrosion.