期刊文献+

断路器变位与工业监控系统联动的实现方案 被引量:8

A Method to Block Position Change of Contacts in Circuit Breakers with Industrial Monitoring System
在线阅读 下载PDF
导出
摘要 无人值班变电站新增工业监控系统后为保证电力系统安全运行提供了重要手段。断路器是电网的重要连接设备,加强对该设备的重点监视十分必要。作者通过增加一个主要由冲击继电器、时间继电器和中间继电器构成的简易联动装置和修改少量工业监控部分设备控制程序来实现当断路器变位后自动触发工业监控系统,相应摄像头自动将该断路器的真实状态上传到监控中心。此外,该联动装置还能帮助电网监控人员及时准确地掌握系统运行状况,其实现方法具有一定的推广价值。 To ensure secure operation of power system it is very important to add industrial monitoring systems in non-attend substations and it is necessary to intensify the monitoring of circuit breakers. The authors present a method to automatically trigger the industrial monitoring system after the position change of contacts in circuit breaker occurs, that is, by means of adding a simply equipped blocking device, which is mainly constituted by pulse relay, timing relay and auxiliary relay, as well as slightly modifying the control program of equipments in industrial monitoring system, when corresponding pick-up head automatically transmit the actual condition of the circuit breaker to monitoring center. In addition, this blocking device can help the supervisory personnel to precisely master the operating situation of power system in time.
出处 《电网技术》 EI CSCD 北大核心 2006年第18期85-88,93,共5页 Power System Technology
基金 湖南省自然科学基金资助项目(02JJY4030)。
关键词 联动 工业监控系统 断路器 数据采集与监控(SCADA) 能量管理系统(EMS) blocking industrial monitoring system circuit breaker supervisory control and data acquisition(SCADA) energy management system(EMS)
  • 相关文献

参考文献15

二级参考文献27

  • 1徐黎明.压气式SF6高压断路器开断性能仿真分析和智能操作:博士学位论文[M].西安:西安交通大学,1998..
  • 2苏方春.超高压断路器智能操作自适应控制单元的研究:硕士学位论文[M].西安:西安交通大学,1998..
  • 3吴伟光 马履中.真空断路器用弹簧操动机构的优化设计(Optimization design of operating device of vacuum circuit breaker)[J].高压电器(High Voltage Apparatus),2002,36(31):14-16.
  • 4蔡洋 彭淳绍 王积荣 等(Cai Yang Peng Chunshao Wang.Jirong et al).电网调度自动化开发与应用的调查及建议(Invcstigation and suggestions on development and application of electric power dispatch automation system)[J].电网技术 (Power System Technology),2000,24(1):4-9.
  • 5ADAMS. User's reference manual[M]. Version 11.0, MDI Corporation, 1999.
  • 6Stammberger H. Force calculations for the movable contact of circuit breakers[C]. 19^th international conf. on electrical contactphenomena. 14-17september, 1998, Nuremberg, Germany.
  • 7Yoshihiro K, Hiroyuki M, Shokichi I. 3-D finite element analysis of electxodynamic repulsion forces instafionary electric contacts taking into account asymmetric shape[J]. [FEE Trans. on Magnetics, 1997,33(2):1994-1999.
  • 8陈晓宁,高电压技术,1998年,24卷,4期
  • 9徐黎明,博士学位论文,1998年
  • 10苏方春,硕士学位论文,1998年