期刊文献+

新型PVC膜银离子选择电极的研制及应用 被引量:1

Preparation and Application of a PVC Membrane Ag (I) Ion Selective Electrode
在线阅读 下载PDF
导出
摘要 以合成的双(N-乙基-N-苯基氨基二硫代甲酸)1,3-丙二醇酯为载体,采用双层膜电位法直接测定了溶剂聚合物膜中载体与金属离子的络合物生成常数.制备并考察了以双(N-乙基-N-苯基氨基二硫代甲酸)1,3-丙二醇酯为载体的银离子选择电极的性能.实验结果表明:该选择电极对银离子有良好的响应性能和高选择性,在10^-3~10^-6mol/L的浓度范围内响应斜率为56.0mV/paAg^+,检测下限为3.7×10^-7mol/L,碱金属、碱土金属及过渡金属离子不干扰银的测定.该电极可作为测定维生素B1药片中维生素B1含量的电位滴定指示电极和水样中银离子含量的直接测定. Trimethylene bis (N- ethyl- N- phenyldithiocarbamate) was used as the ionophore in solvent polymeric membrane. The ionophore-metal ion complex formation constants in solvent polymeric membrane were determined directly by potentiometry with a two-layer membrane electrode. A silver ion selective electrode was prepared and characterized with trimethylene bis (N-ethyl-N-phenyldithiocarbamate) as ionophore. The membrane electrode exhibited a good response to silver (I) with a slope of 56.0 mV/pa^,+ in the concentration range 10^-3~10^-6 mol/L AgNO3 solution, and the detection limit is 3.7×10^-7 mol/L. The electrode has a highly selectivity for silver ion over alkali, alkaline earth and common transition metal ions. The electrode was used as the indicator electrode in titration of halide ions and Vitamin B1 in Vitamin B1 tablets with silver ion. The proposed electrode has also been used for the direct determination of silver ion in water sample.
出处 《河南师范大学学报(自然科学版)》 CAS CSCD 北大核心 2006年第3期111-114,共4页 Journal of Henan Normal University(Natural Science Edition)
基金 河南省教育厅自然科学基金(200510459014)
关键词 双(N-乙基-N-苯基氨基二硫代甲酸)1 3-丙二醇酯 离子选择电极 银离子 trimethylene bis (N-ethyl-N-phenyldithiocarbamate) ion-selective electrode silver ion
  • 相关文献

参考文献12

  • 1Bailey P L.Analysis with Ion-Selective Electrodes[M].Gt Yarmouth,Norfolk,U.K.,Galliard Ltd.,1976.
  • 2Siswanta D,Nagatsuka K,Yamada H,et al.Structural Ion Selectivity of Thiacrown Ether Compounds with a Bulky Subunit and Their Application as an Ion Sensing Component for an Ion Selective Electrode[J].Anal Chem,1996,68(23):4 166-4 172.
  • 3Mashhadizadeh M H,Shamsipur M.Silver(I)-Selective Membrane Electrode Based on Hexathia-18-Crown-6[J].Anal Chim Acta,1999,381(1):111-116.
  • 4Zeng X,Weng L,Chen L,et al.Improved Silver Ion-Selective Electrodes Using Novel l,3-Bis(2-benzothiazolyl) Thioalkoxy-p-tert-Butyl Calix[4]arene[J].Tetrahedron Lett,2000,41(25):4 917-4 921.
  • 5Chen L,Ju H,Zeng X,et al.Silver Ion-Selective Electrodes Based on Novel Containing Benzothiazolyl Calix[4]arene[J].Anal Chim Acta,2001,437 (2):191-197.
  • 6Liu Y,Zhao B T,Chen L X,et al.Liquid Membrane Transport and Silver Selective Electrode Based on Novel Bis(3-pyridinecarboxylate) Calix[4]arene as Ionophore[J].Microchem J,2000,65 (1):75-79.
  • 7Mahajan R K,Kumar M,Sharma V,et al.Silver(I) ion-selective membrane based on Schiff Base p-tert-butylcalix[4]arene[J].Analyst,2001,126 (4):505-507.
  • 8吕鉴泉,何锡文,曾宪顺,万其进,张正之.新型钳状芳杂环杯[4]芳烃修饰电极对银离子的分子识别研究[J].高等学校化学学报,2003,24(3):398-403. 被引量:8
  • 9吕鉴泉,陆江林,周兴旺,何锡文.以新型杯[6]衍生物为探针的银离子选择性电极研究[J].分析科学学报,2003,19(1):30-32. 被引量:3
  • 10Mi Y M,Bakker E.Determination of Complex Formation Constants of Lipophilic Neutral Ionophores in Solvent Polymeric Membranes with Segmented Sandwich Membranes[J].Anal Chem,1999,71(23):5 279-5 287.