期刊文献+

新型杯芳烃银离子选择电极的研究 被引量:8

Silver Ion Selective Electrode Based on a Novel Substituted Calix[4]arene
在线阅读 下载PDF
导出
摘要 报道了5,11,17,23-四(1,1.二甲基乙基)-25,27-二羟基-26,28-二[(2-乙基硫)乙氧基]杯[4]芳烃为银离子载体的PVC膜电极的研制。该银离子选择电极不仅对银离子有良好的灵敏度和高选择性,在10-1~10-5 mol/L浓度范围内有良好的线性,能斯特响应为56 mV/pcag·(25℃),碱金属、碱土金属及过渡金属离子不干扰银的测定;而且对某些阴离子也表现出近似能斯特响应(50mV/pcx)。用该电极对人工试样中银含量进行测定,结果与原子吸收光度法相符。 A novel thioether - substituting calix [4] arene derivative 5, 11, 17, 23 - tetrakis (1, 1 - dimethyl ethyl ) - 25, 27- dihydroxy -bis [ (2-ethylthio) ethoxy ] calix [4] arene has been tested as ionophore in a Ag + - PVC electrode. The Ag -+ PVC electrode exhibited a good linear response of 56 mV/pcAg+ in the range of 10 -5 - 10 -l mol/L, and fairly good dis criminating ability towards Ag + in comparison with some ions of alkali, alkaline earth, transition and heavy metals. The electrode displayed a good response to some an- ions(50 mV/pcx ) too. The analysis result of a synthetic sample by this method was in agreement with that by atomic absorption spectrometry.
机构地区 南开大学化学系
出处 《分析测试学报》 CAS CSCD 2000年第6期17-20,共4页 Journal of Instrumental Analysis
基金 国家自然科学基金资助项目(29975014)
关键词 杯[4]芳烃 银离子选择电极 测定 Thioether Calix[4]arene Silver ion Anion Ion selective electrode
  • 相关文献

参考文献8

  • 1PUNGOR E,TOTH K,HRABECZY-PALL A.Selectivity coefficients of ion-selective electrodes[].Pure and Applied Chemistry.1979
  • 2BOHMER V.Calixarenes, macrocycles with (almost) unlimited possibilities[].Angewandte Chemie International Edition.1997
  • 3O’CONNOR K,SVEHLA G,HARRIS S J,et al.Calixarene-based potentiometric ion-selective electrodes for silver[].Talanta.1992
  • 4GEHRIG P M,MORF W E,WELTI M,et al.Catalysis of ion transfer by tetraphenylborates in neutral carrier-based ion-selectiveelectrodes[].Helvetica Chimica Acta.1990
  • 5BAKKER E.Origin of anion response of solvent polymeric membrane based silver ion-selective electrodes[].Sensors and Actua-tors B.1996
  • 6HUSER M,GEHRIG P M,MORF W E,et al.Membrane technology and dynamic response of ion-selective liquid-membraneelectrodes[].Analytical Chemistry.1991
  • 7MALINOWSKA E,BRZOZKA Z,KASIURA K,et al.Silver selective electrodes based on thioether functionalized calix[4]arenes asionophores[].Analytica Chimica Acta.1994
  • 8BUHLMANN P,PRETSCHE E,BAKKER E.Ion-selective electrodes and bulk optodes[].Chemical Reviews.1998

同被引文献53

  • 1夏新泉,张海丽,吕鉴泉.含硫杯[4]芳烃衍生物修饰电极伏安行为的研究[J].化学研究与应用,2006,18(7):848-850. 被引量:2
  • 2李连元,张岚.荧光光度法测定生活饮用水中的铝[J].中国卫生检验杂志,2006,16(10):1183-1184. 被引量:13
  • 3秦巧燕,贾陈忠,熊康.铬天青S分光光度法测定痕量铝的研究[J].环境科学导刊,2007,26(2):88-90. 被引量:7
  • 4李忠玉,徐松,黄新,张复实,笠谷和男.一种近红外光记录与存储材料——克酮酸染料的三阶非线性光学性质[J].感光科学与光化学,2007,25(4):241-248. 被引量:4
  • 5Shamsipur M, Javanbakht M, Lippolis V, et al. Novel Ag^+ ion- selective electrodes based on two new mixed azathloether crowns containing a 1, 10-phenanthroline sub - unit[J]. Anal. Chim. Acta, 2002, 462(2) : 225 -234.
  • 6Liu D, Liu J, Tian D, et al. Polymeric membrane silver - ion selective electrodes based on bls(dialkyldithiophosphates) [J]. Anal. Chim. Acta, 2000,416(2) : 139 -144.
  • 7Eramo F D', Silber J J, Sereno L E, et al. Electrochemical detection of silver ions and the study of metal- polymer interactions on a polybenzidine fdm electrode[J]. J. Electmanal. Chem.,2000, 494(1) :60 -68.
  • 8Sulka G D , Jaskula M. Kinetics based determination of trace amounts of silver at the excess of copper ions[J].Anal. Chim. Acta, 1999, 394(2 -3) :185 - 194.
  • 9Koh T, Sugimoto T. Extractive spectrophotometric deterruination of silver( I ) at the 10^-7 M level using 1, 10 -phenanthroline and tetrabromophenolphthaleln ethyl ester[J]. Anal. Chim. Acta, 1996,333(1 -2) :167 - 173.
  • 10Argekar A A, Kulkami M J, Mathur J N, et al. ICP -AES determination of silver after chemical separation from uranium matrlx[J] . Talanta. 1995, 42(12):1 937-1 942.

引证文献8

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部