1Khandurina J,Guttman A.Bioanalysis in microfluidic devices[J].J Chromatogr-A,2002,943(2):159
2Chantal KM,Volker S.Applications of LIGA technology to precision manufacturing of high-aspect-ratio micro-components and -systems:a review[J].Microelectronics J,2004,35(2):131
3Kakehi K,Oda Y.Fluorescence polarization:analysis of carbohydrate-protein interaction[J].Anal Biochem,2001,297(2):111
4Lapos JA,Manica DP,Ewing AG.Dual fluorescence and electrochemical detection on an electrophoresis microchip[J].Anal Chem,2002,74(14):3348
6Ramsey JD,Jacobson SC,Culbertson CT,et al.High-efficiency,two-dimensional separations of protein digests on microfluidic devices[J].Anal Chem,2003,75(15):3758
7Lagally ET,Medintz I,Mathies RA.Single-molecule DNA amplification and analysis in an integrated microfluidic device[J].Anal Chem,2001,73(3):565
8Zhou X,Liu D,Zhong R.Determination of SARS-coronavirus by a microfluidic chip system[J].Electrophoresis,2004,25(17):3032
9Liu S,Shi Y,Ja WW,et al.Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels[J].Anal Chem,1999,71(3):566
10Koutny L,Schmalzing D,Salas SO,et al.Eight hundred-base sequencing in a microfabricated electrophoretic device[J].Anal Chem,2000,72(14):3388
3Deisingh A K, Thompson M. Strategies for the detection of Escherlchia coli O157:H7 in foods[J]. J Appl Microbiol, 2004, 96(3): 419-429.
4Jing G, Polaczyk A, Oerther D B, et al. Development of a microfluidic biosensor for detection of environmental mycobacteria[ J]. Sens Actuators B Chem, 2007, 123(1) : 614 -621.
5Chen Z, Mauk M G, Wang J, et al. A microfluidic system for salivabased detection of infectious diseases[J]. Ann N Y Acad Sci, 2007, 1098 : 429 -436.
6Ikeda M, Yamaguchi N, Tani K, et al. Rapid and simple detection of food poisoning bacteria by bead assay with a microfluidic chip-based system[J]. J Microbiol Methods, 2006, 67(2) : 241 -247.
7Beyor N, Seo T S, Liu P, et al. Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection [ J ]. Biomed Microdevices, 2008, 10(6): 909-917.
8Lee W C, Lien K Y, Lee G B, et al. An integrated microfluidic system using magnetic beads for virus detection [J]. Diagn Mierobiol Infect Dis, 2008,60(1):51-58.
9Lee S J, Park J S, Im H T, et al. A microfluidic ATP-bioluminescence sensor for the detection of airborne microbes [J]. Sens Actuators B Chem, 2008, 132(2) : 443 -448.
10Yang L, Banada P P, Chatni M R,et al. A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with inununoeapture of low numbers of Listeria monocytogenes[J]. Lab Chip, 2006, 6(7) : 896 -905.