期刊文献+

基于双端不同步数据故障定位的中位修正法 被引量:7

Novel Correcting Method for Fault Location Based on Two-terminal Asynchronous Data
在线阅读 下载PDF
导出
摘要 提出了基于双端不同步数据的故障定位(它不受过渡电阻影响,比单端算法定位准确)新算法,该算法利用故障前、后的电压电流信息对线路参数和故障距离分别迭代求解,同时综合修正线路长度、线路参数及电压电流等误差。仿真计算证明,该法估算线路参数和故障距离较准确,且不受故障类型、线路参数变化和故障线路长度误差等因素影响,鲁棒性较强。 The method of fault location which use data from two ends of the transmission line are not effected by the fault resistance and are more sensitive than those methods which use one-terminal data. So more attention are paid to them nowadays. A novel method based on two-terminal data is presented here, which can use the voltages and currents before and after fault to calculate the parameter of line and the point of fault iteratively and respectively. The algorithm can make a dynamic and integrative correction to the errors of voltage, current and the length and parameter of the line etc. The simulation proves that this method can estimate the line parameter and the fault distance more accurately. And the fault type, the change of line parameter, and the error of fault line has little influence to this method. So this method is more robust
出处 《高电压技术》 EI CAS CSCD 北大核心 2005年第9期1-4,共4页 High Voltage Engineering
关键词 故障定位 双端不同步 参数估计 fault location unsynchronized two-terminal parameter estimate
  • 相关文献

参考文献14

  • 1Jiang J A, Yang J Z, Lin Y H, et al. An adaptive PMU based fault detection/location technique for transmission lines-Part I: Theroy and algorithms[J]. IEEE Trans on Power Delivery, 2000, 15(2): 486-493.
  • 2Chen C S, Liu C W, Jiang J A. A new adaptive PMU based protection scheme for transposed/untransposed parallel transmission lines[J]. IEEE Trans on Power Delivery, 2002, 17(2) : 395-404.
  • 3Kezunovic M, Mrkic J, Perunicic B. An accurente fault location algorithm using synchronized sampling E J3. Electric Power Systems Research,1994, 29(1):161-169.
  • 4Novosel D, Hart D G, Udren E, et al. Unsynchronized two-terminal fault location estimation[J]. IEEE Trans on Power Delivery, 1996, 11(1):130-138.
  • 5Girgis A A, Hart D G, Peterson W L A new fault location technique for two and three terminal lines[J]. IEEE Trans on Power Delivery, 1992, 7(1): 98-107.
  • 6梁军,孟昭勇,车仁飞,李仁俊.精确双端故障测距新算法[J].电力系统自动化,1997,21(9):24-27. 被引量:41
  • 7叶一麟 蔡德礼.系统参数变化对输电线路故障测量精度的影响[J].重庆大学学报,1984,(4):70-78.
  • 8全玉生,杨敏中,王晓蓉,严璋,李晓兵,于峥,康林贤,佟科,刘晓峰,侯成林.双端测距中的自适应线路参数在线估计[J].电力系统自动化,2000,24(11):26-30. 被引量:24
  • 9钱峰,陈义飞,龚庆武.一种新型双端时域故障定位算法[J].高电压技术,2005,31(2):81-83. 被引量:3
  • 10黄雄,王志华,尹项根,张哲.高压输电线路行波测距的行波波速确定方法[J].电网技术,2004,28(19):34-37. 被引量:94

二级参考文献45

  • 1万罡,赵向平,韩智,林晓明.数字信号处理器在电测仪表中的运用[J].科技进步与对策,2000,17(6):60-61. 被引量:4
  • 2胡帆,刘沛,程时杰.高压输电线路故障测距算法仿真研究[J].中国电机工程学报,1995,15(1):67-72. 被引量:60
  • 3黄志明.我国超高压输电线路的建设和发展[J].中国电力,1996,29(12):9-12. 被引量:4
  • 4梁合庆 蔡德礼.关于高性能数字滤波器的研究[J].电力系统自动化,1985,9(6):23-30.
  • 5叶一麟 蔡德礼.系统参数变化对输电线路故障测距精度的影响[J].重庆大学学报,1984,(4):70-78.
  • 6全玉生.高压架空输电线路故障测距新算法的研究:[博士学位论文].西安:西安交通大学,1999..
  • 7岳嵘.基于工频量的故障测距方法的研究:[硕士学位论文].西安:西安交通大学,1997..
  • 8李必涛.基于DSP的智能型电力监测仪的研究.全国高校电力系统及其自动化专业第十五届学术年会[M].,1999..
  • 9李仁俊,电力系统自动化,1993年,17卷,6期
  • 10陈珩,电力系统稳态分析