期刊文献+

阳离子交换分离-发射光谱法测定金属铀或八氧化三铀中微量硼 被引量:4

CATION EXCHANGE SEPARATION-EMISSION SPECTROGRAPHIC DETERMINATION OF BORON IN URANIUM METAL OR URANIUM OXIDE
在线阅读 下载PDF
导出
摘要 文章叙述了阳离子交换分离-发射光谱法测定金属铀或八氧化三铀中微量硼的方法。在试样溶解和蒸发过程中,采用甘露醇络合硼以防止硼的蒸发损失,用阳离子交换分离法将硼与大量铀及其它多种阳离子分离后,用以氟化钠为外加基体,铍为内标,平头石墨电极,交换电弧为激发光源的溶液干渣光谱法测定硼。取样0.4g时,测定下限可达0.012ppm。此时方法的相对标准偏差为±18%,当硼含量为0.04ppm时,相对标准偏差为±9%,方法回收率为108-111%,方法简单、快速、测定下限低、干扰小,经与其它分析方法核对数据,证明方法可靠,可满足测定要求。 The spectrochemical method of determination of extremely low concentration,of boron in uranium is described here. The sample is dissolved in HNO_3 aftermannitol is added to complex boron. Then boron is separated from uranium bycation exchange method. After that, the solution of boron is evaporated to dry-ness at low temperature and redissolved in 0.5ml solution containing NaF as anew matrix and Be as an internal standard. Then it is evaporated to dryness oncarbon electrode and exciteded by AC arc. The proposed method can determine as little as 0.012ppm boron with 0.4gsamples. The percentage of recovery is(108~111)%. The relative standard deviationis less than±18% when concentration of boron is 0.012ppm, and less than±9%when concentration of boron is 0,04ppm. The method is simple, rapid sensitiveand reliable. The analytical results of several standard samples agree with those obtainedby other methods.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 1989年第3期40-44,共5页 Atomic Energy Science and Technology
关键词 阳离子交换 发射光谱 测定 Boron Uranium Ion-exchange Spectrochemical determination
  • 相关文献

参考文献3

  • 1姜延林,原子能科学技术,1975年,3期,221页
  • 2覃善章,理化检验通讯,1966年,2卷,60页
  • 3关景素,1964年

同被引文献403

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部