摘要
报道了以TritonX-100为增溶剂,高碘酸钾氧化PAN催化光度法测定痕量锰的新体系.方法的检出限为3.6×10(-3)μg/mL,精密度为2.4%(n=9),线性范围为0.10~1.3μg/25mL,可用于谷物样品中锰的测定.
The indicator reactions for using in kinetic spectrophotometry are necessarily those reactions of homogeneous system.If the reactants or the products are insoluble,these reactions can not be monitored by spectrophotometry.The authors change non-homogeneous systems into analog-homogeneous systems extending the range of selecting indicator reactions of kinetic spectrophotometry by adding surfactant to insoluble reactions with the solubilizing effect of surfactant.A new catalytic spectrophotometric system for the determination of trace of Mn(Ⅱ)has been developed.This method is based on the catalytic oxidation of 1-2-pyridylazo)-2-naphthol by potassium periodate in the presence of Triton X-100 as a solubilized agent.The detection limit is 3.6×10 ̄(-3)μg/mL,the relative standard deviation is 2.4%,the linear range of determination is 0.1~1.3 μg/25 mL for Mn(Ⅱ). This method has been successfully used to determine Mn in cereal samples.
出处
《高等学校化学学报》
SCIE
EI
CAS
CSCD
北大核心
1995年第12期1861-1864,共4页
Chemical Journal of Chinese Universities
基金
福建省自然科学基金
关键词
光度法
吡啶偶氮
萘酚
锰
谷扬