摘要
总结了用于混凝土结构的Ag/AgCl和Pb两种电极,在室内、外及钢筋混凝土码头梁板内的试验情况,结果表明.固定式Ag/AgCl电极电位变化较小.制备安装简单,可作为混凝土中埋置的参比电极,可更换式Ag/AgCl电极电位稳定,寿命长,在工程应用中。
The use of Ag/AgCl electrode and Ph electrode as references under different experimental conditions in laboratory, outdoors and in reinforced concrete slabs are summarized. It is shown that the potential drift of the fixed Ag/AgCl electrode is small, suitable for using as enbedded reference electrode inconcrete structure with its simple preparation and installation, while the replaceable Ag / AgCl electrode is steady in potential and have a long service life, good for long effective reference'electrode in engineering acplication.
出处
《腐蚀科学与防护技术》
CAS
CSCD
1994年第3期284-287,共4页
Corrosion Science and Protection Technology
关键词
参比电极
混凝土结构
腐蚀监测
reference electrode, concrete structure, corrosion monitoring