期刊文献+

偏最小二乘分光光度法同时测定铌和钽 被引量:1

THE SIMULTANEOUS DETERMINATIONS OF NIOBIUM AND TANTALUM BY PARTIAL LEAST SQARES SPECTROPHOTOMETRIC METHOD
在线阅读 下载PDF
导出
摘要 本文研究了以5-Br-PADAP作显色剂,用偏最小二乘(PLS)分光光度法同时测定铌和钽。对模拟矿样和实际矿样的测定结果表明,测定铌钽的相对标准偏差分别小于0.73‰和0.63‰,平均相对误差小于10%,当铌钽含量太小时,可达13%。平均回收率在91%至99%之间,这表明该方法能用于选矿过程中铌钽的测定。 In this paper, thc simultancous de terminations of niobium and tantalum are studied by means of partial least sqares ( PLS ) spec tcopho tomelt ic method, in. wjocp 5-Br-PADAP is used as a developing reagent. The results of delermining niobium and tantalum in simulated and practical ore samples show that the relative standard deviations are less than 0.73?? and 0.63??, tespectively, and the average celative errors arc less than 10%, However it may reach 13% when amounts of niobium and tantalum are too low. They also show that average recovery ratio is between 91.0% and 99,4%, Therefore this method can be applied to the determinations of niobium and tantalum in dressing process.
出处 《赣南师范学院学报》 1993年第2期76-82,共7页 Journal of Gannan Teachers' College(Social Science(2))
关键词 偏最小二乘法 分光光度法 测定 partial Least sqares Spectrophotometry simultaneous determinations of mult icomponent Niobium and tantalum
  • 相关文献

参考文献3

二级参考文献10

  • 1何锡文,分析化学,1987年,15卷,6期,495页
  • 2何锡文,分析化学,1986年,14卷,1期,34页
  • 3罗国安,药物分析杂志,1986年,6卷,5期,316页
  • 4王义明,中国化学会第二届计算分析学术会议论文集,1988年
  • 5王镇浦,中国化学会第三次全国多元络合物光度分析会议论文集,1987年
  • 6张济新,计算机与应用化学,1987年,4卷,1期,40页
  • 7过乃蓉,分析化学,1983年,11卷,6期,408页
  • 8何锡文,分析化学,1979年,7卷,3期,179页
  • 9郑用熙.分析化学中的数理统计方法[M]科学出版社,1986.
  • 10王镇浦,罗国安,周国华,姚成.PLS法在同时分光光度测定痕量金属离子中的应用[J].分析化学,1989,17(4):317-320. 被引量:25

共引文献83

同被引文献91

引证文献1

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部