The X-ray diffraction peak-shift method was introduced into the determination of deformation fault probability (a) of Fe-Mn-Si alloys with various Mn contents and thermomechanical cycling numbers. The precise lattice ...The X-ray diffraction peak-shift method was introduced into the determination of deformation fault probability (a) of Fe-Mn-Si alloys with various Mn contents and thermomechanical cycling numbers. The precise lattice constants required were obtained by numerical calculation instead of using standard sample without any fault. The influence of internal stress on the determined a has been evaluated, and the caused relative error was determined as about 4% and thus negligible. The results show that the deformation fault probability increases with decreasing Mn-content and increasing cycle number, which are qualitatively consistent with those results of Psf determined by peak-broadening method.展开更多
This paper studies the viscid and inviscid fluid resonance in gaps of bottom mounted caissons onthe basis of the plane wave hypothesis and full wave model, The theoretical analysis and the numerical results demonstrat...This paper studies the viscid and inviscid fluid resonance in gaps of bottom mounted caissons onthe basis of the plane wave hypothesis and full wave model, The theoretical analysis and the numerical results demonstrate that the condition for the appearance of fluid resonance in narrow gaps is kh=(2n+1)π (n=0, 1, 2, 3 ), rather than kh=nn (n=0, 1, 2, 3, ...); the transmission peaks in viscid fluid are related to the resonance peaks in the gaps. k and h stand for the wave number and the gap length. The combination of the plane wave hypothesis or the full wave model with the local viscosity model can accurately determine the heights and the locations of the resonance peaks. The upper bound for the appearance of fluid resonance in gaps is 2b/L〈l (2b, grating constant; L, wave length) and the lower bound is h/b〈~ l. The main reason for the phase shift of the resonance peaks is the inductive factors. The number of resonance peaks in the spectrum curve is dependent on the ratio of the gap length to the grating constant. The heights and the positions of the resonance peaks predicted by the present models agree well with the experimental data.展开更多
基金The present work was financially supported by the Advanced Materials Center Foundation of Shanghai, China (No. 99JC14019).
文摘The X-ray diffraction peak-shift method was introduced into the determination of deformation fault probability (a) of Fe-Mn-Si alloys with various Mn contents and thermomechanical cycling numbers. The precise lattice constants required were obtained by numerical calculation instead of using standard sample without any fault. The influence of internal stress on the determined a has been evaluated, and the caused relative error was determined as about 4% and thus negligible. The results show that the deformation fault probability increases with decreasing Mn-content and increasing cycle number, which are qualitatively consistent with those results of Psf determined by peak-broadening method.
基金financially supported by the National Key R&D Program of China(Grant No.2017YFC0405402)
文摘This paper studies the viscid and inviscid fluid resonance in gaps of bottom mounted caissons onthe basis of the plane wave hypothesis and full wave model, The theoretical analysis and the numerical results demonstrate that the condition for the appearance of fluid resonance in narrow gaps is kh=(2n+1)π (n=0, 1, 2, 3 ), rather than kh=nn (n=0, 1, 2, 3, ...); the transmission peaks in viscid fluid are related to the resonance peaks in the gaps. k and h stand for the wave number and the gap length. The combination of the plane wave hypothesis or the full wave model with the local viscosity model can accurately determine the heights and the locations of the resonance peaks. The upper bound for the appearance of fluid resonance in gaps is 2b/L〈l (2b, grating constant; L, wave length) and the lower bound is h/b〈~ l. The main reason for the phase shift of the resonance peaks is the inductive factors. The number of resonance peaks in the spectrum curve is dependent on the ratio of the gap length to the grating constant. The heights and the positions of the resonance peaks predicted by the present models agree well with the experimental data.