Production of this crop is experiencing significant challenges, resulting in a decline in seed and fiber quality. To address this challenge, generations of high-performance cotton plants of the Gossypium hirsutum L. s...Production of this crop is experiencing significant challenges, resulting in a decline in seed and fiber quality. To address this challenge, generations of high-performance cotton plants of the Gossypium hirsutum L. species have been developed and are currently being commercialized. This study evaluated the impact of gin types on the agro-industrial quality of cotton in Côte d’Ivoire. To this end, cotton from the G3, R1, and R2 generations was harvested, sampled, and ginned on machines with 10 and 170 saws in the localities of Ouangolodougou, Ferkessédougou, Korhogo, M’Bengué, Boundiali, Séguéla, and Mankono, as well as at the Centre National de Recherche Agronomique CNRA) in Bouaké. The results demonstrated that cotton fibers obtained from ginning on 10-saw machines exhibited superior quality compared to those from 170-saw machines. Fiber length, fiber length uniformity, and short fiber rate exhibited the highest deviations according to gin type. The use of 170-saw gins resulted in a notable decline in quality. Conversely, micronaire index, fiber tenacity and elongation, and reflectance remained consistent across machine types. These results will enable us to more effectively regulate and advise cotton-processing factories, which primarily utilize 170-saw gins to enhance agro-industrial quality in Côte d’Ivoire. Furthermore, these results will assist breeders in incorporating them into their processes to enhance the quality of the varieties they offer to farmers.展开更多
In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the me...In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the measurement requirements of wide bandwidth and high accuracy spectral lines,we built a CTS system with an analysis bandwidth of 1 GHz and a frequency resolution of 100 kHz around the surface acoustic wave(SAW)chirp filter with a bandwidth of 1 GHz.In this paper,the relationship between the CTS nonlinear phase error shift model and the basic measurement parameters is studied,and the effect of CTS phase mismatch on the pulse compression waveform is analyzed by simulation.And the expander error optimization method is proposed for the problem that the large nonlinear error of the expander leads to the unbalanced response of the CTS system and the serious distortion of the compressed pulse waveform under large bandwidth.It is verified through simulation and experiment that the method is effective for reducing the root mean square error(RMSE)of the phase of the expander from 18.75°to 6.65°,reducing the in-band standard deviation of the CTS frequency resolution index from 8.43 kHz to 4.72 kHz,solving the problem of serious distortion of the compressed pulse waveform,and improving the uneven CTS response under large bandwidth.展开更多
文摘Production of this crop is experiencing significant challenges, resulting in a decline in seed and fiber quality. To address this challenge, generations of high-performance cotton plants of the Gossypium hirsutum L. species have been developed and are currently being commercialized. This study evaluated the impact of gin types on the agro-industrial quality of cotton in Côte d’Ivoire. To this end, cotton from the G3, R1, and R2 generations was harvested, sampled, and ginned on machines with 10 and 170 saws in the localities of Ouangolodougou, Ferkessédougou, Korhogo, M’Bengué, Boundiali, Séguéla, and Mankono, as well as at the Centre National de Recherche Agronomique CNRA) in Bouaké. The results demonstrated that cotton fibers obtained from ginning on 10-saw machines exhibited superior quality compared to those from 170-saw machines. Fiber length, fiber length uniformity, and short fiber rate exhibited the highest deviations according to gin type. The use of 170-saw gins resulted in a notable decline in quality. Conversely, micronaire index, fiber tenacity and elongation, and reflectance remained consistent across machine types. These results will enable us to more effectively regulate and advise cotton-processing factories, which primarily utilize 170-saw gins to enhance agro-industrial quality in Côte d’Ivoire. Furthermore, these results will assist breeders in incorporating them into their processes to enhance the quality of the varieties they offer to farmers.
文摘In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the measurement requirements of wide bandwidth and high accuracy spectral lines,we built a CTS system with an analysis bandwidth of 1 GHz and a frequency resolution of 100 kHz around the surface acoustic wave(SAW)chirp filter with a bandwidth of 1 GHz.In this paper,the relationship between the CTS nonlinear phase error shift model and the basic measurement parameters is studied,and the effect of CTS phase mismatch on the pulse compression waveform is analyzed by simulation.And the expander error optimization method is proposed for the problem that the large nonlinear error of the expander leads to the unbalanced response of the CTS system and the serious distortion of the compressed pulse waveform under large bandwidth.It is verified through simulation and experiment that the method is effective for reducing the root mean square error(RMSE)of the phase of the expander from 18.75°to 6.65°,reducing the in-band standard deviation of the CTS frequency resolution index from 8.43 kHz to 4.72 kHz,solving the problem of serious distortion of the compressed pulse waveform,and improving the uneven CTS response under large bandwidth.