We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-...We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.展开更多
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl...Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.展开更多
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi...Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.展开更多
A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the ...A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the phase difference between the Rayleigh scattering from two sections of the fiber. A new demodulation method called the inverse transmission matrix demodulation scheme is utilized to demodulate the distributed phase from the backward scattering along the long fiber, The experimental results show that the 120°-phase-difference inter- ferometer φ-OTDR can detect the phase along the 3km fiber, and the acoustic signal within the whole human hearing range of 20 Hz-20 kHz is reproduced accurately and quickly.展开更多
Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short ...Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short scan time, phase errors, especially spatially-dependent phase shift, caused by a variety of factors may result in misplacement of fat and water voxels. In this paper, a novel phase correction algorithm was used to calibrate those phase errors during image reconstruction. This algorithm corrects phase by region growing, employing both the magnitude and the phase information of image pixels. Phantom and in vivo imagings were performed to validate the technique. As a result, excellent fat-suppressed images were acquired by using single-acquisition phase-sensitive SSFP with phase correction.展开更多
Objective:Late gadolinium enhancement(LGE) patterns of cardiovascular magnetic resonance (CMR) relying on PSIR(phase-sensitive inversion recovery sequence) techniques had been used to determine the characteristics of ...Objective:Late gadolinium enhancement(LGE) patterns of cardiovascular magnetic resonance (CMR) relying on PSIR(phase-sensitive inversion recovery sequence) techniques had been used to determine the characteristics of LGE in apical hypertrophic cardiomyopathy(ApHCM). Methods:Forty patients pure ApHCM[age,(60.2±10.4) years,31 men]were enrolled.LGE images were acquired using PSIR,and analyzed using a 17-segment model.Summing the LGE areas in all short axis slices yielded the total volume of late enhancement,which was subsequently presented as a proportion of total LV myocardium(%LGE).Results:Mean maximal apical wall thickness was(17.9±2.3) mm,and mean left ventricular(LV) ejection fraction was(67.7±8.0)%.LGE was detected in 130 segments of 30 patients(75.0%),occupying(4.9±5.5)% of LV myocardium.LGE was mainly detected at the junction between left and right ventricles in 12(30%) and at the apex in 28(70%),although LGE-positive areas were widely distributed,and not limited to the apex.Focal LGE at the non-hypertrophic LV segments was found in some ApHCM patients,even without LGE of hypertrophied apical segments.Conclusions:LGE was frequently observed not only in the thickened apex of the heart but also in other LV segments,irrespective of the presence or absence of hypertrophy.The simple presence of LGE on CMR was not representative of adverse prognosis in this population.展开更多
Objective:To determine the deference between phase sensitive magnetic resonance(MR) imaging and magnitude reconstruction to detect infracted myocardium.Methods:Twenty patients(16 men;4 women;mean age,56 years),experie...Objective:To determine the deference between phase sensitive magnetic resonance(MR) imaging and magnitude reconstruction to detect infracted myocardium.Methods:Twenty patients(16 men;4 women;mean age,56 years),experienced Q-wave myocardial infarction 2 weeks earlier were examined with a 3.0-T MR system 10 minutes after administration of 0.1 mmol/kg body weight gadobenate dimeglumine.To determine the optimal TI,a TI scout sequence was used.A segmented 2D IR true fast imaging with steady-state precession(trueFISP) sequence that produces both phase-sensitive and magnitude-reconstructed images were used at TI values of 200-600 msec(TI values were varied in 100-msec steps) and at optimal TI(mean value,330 msec).Contrast- noise ratios(CNRs) of normal and infarcted myocardium and the area of infarcted myocardium were determined.Two-tailed unpaired sample Student t test was used to compare CNRs,and area of infarction.Results:MMean CNR phase-sensitive and magnitude-reconstructed images at optimal TI(mean value,330 msec) were 6.2,and 6.1,respectively.For a TI of 200 msec,CNR values were 5.5,and 4.2,respectively;for TI of 600 msec,CNR values were 5.8 and 4.3,respectively.Area of infarcted myocardium was underestimated on magnitude-reconstruction images(P = 0.002-0.03) for short TI values(ie.,200 msec) but not on phase sensitive reconstructed when compared with IR tureFISP images obtained at optimal TI.Conclusions: LPhase-sensitive image reconstruction results in reduced need for precise choice of TI and more consistent image quality.展开更多
We study the colour-locked twin-noisy-field correlation effects in the fifth-order nonlinear susceptibility of ultrafast polarization beats in a cascade four-level system. More importantly, the fifth-order phase-sensi...We study the colour-locked twin-noisy-field correlation effects in the fifth-order nonlinear susceptibility of ultrafast polarization beats in a cascade four-level system. More importantly, the fifth-order phase-sensitive heterodyne detection of ultrafast polarization beats has been exploited. The fifth-order nonlinear optical response can be controlled and modified through the colour-locked correlation of twin noisy fields. Thus, this method with the phase dispersion information is a good way to measure the real and imaginary parts of the fifth-order nonlinear susceptibility.展开更多
We present a theoretical scheme for broadband multi-channel quantum noise suppression and phase-sensitive modulation of continuous variables in a coupled resonant system with quantum entanglement properties.The effect...We present a theoretical scheme for broadband multi-channel quantum noise suppression and phase-sensitive modulation of continuous variables in a coupled resonant system with quantum entanglement properties.The effects of different coupling strengths,pumping power in suppressing quantum noise and controlling the width of quantum interference channels are analyzed carefully.Furthermore,quantum noise suppression at quadrature amplitude is obtained with phase-sensitive modulation.It shows that the entanglement strength of the output field and the quantum noise suppression effect can be enhanced significantly by a strong pumping filed due to interaction of pumping light with the nonlinear crystal.The full width at half maxima(FWHM)of the noise curve at the resonant peak(△=0 MHz)is broadened up to 2.17 times compared to the single cavity.In the strong coupling resonant system,the FWHM at △=0 MHz(△=±3.1 MHz)is also broadened up to 1.27(3.53)times compared to the weak coupling resonant system case.The multi-channel quantum interference creates an electromagnetically induced transparent-like line shape,which can be used to improve the transmission efficiency and stability of wave packets in quantum information processing and quantum memory.展开更多
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho...X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors.展开更多
The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process th...The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process that leads to a significant deterioration of non-uniformity when scaling up to larger areas.Since the performance of gaseous detectors is highly dependent on the choice of working gas,optimizing the gas mixture offers a promising solution to improve the uniformity performance.This paper addresses these challenges through a combined approach of simulation based on Garfield++and experimental studies.The simulation investigates the properties of different mixing fractions of gas mixtures and their impact on detector performance,including gain uniformity and time resolution.To verify the simulation results,experimental tests were conducted using a multi-channel PICOSEC MM prototype with different gas mixtures.The experimental results are consistent with the findings of the simulation,indicating that a higher concentration of neon significantly improves the detector’s gain uniformity.Furthermore,the influence of gas mixtures on time resolution was explored as a critical performance indicator.The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance.展开更多
To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the...To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the glass-metal hetero-bonding process.This study focuses on the analysis and experimental re-search of the bonding layer in the integrated structure.By optimizing the structural configuration and select-ing suitable bonding processes,the reliability of the telescope system is enhanced.The research indicates that using J-133 adhesive achieves the best performance,with a bonding layer thickness of 0.30 mm and a metal substrate surface roughness of Ra 0.8.These findings significantly enhance the reliability of the optical sys-tem while minimizing potential risks.展开更多
The study of the charge conjugation and parity(CP)violation of hyperon is the precision frontier for probing possible new CP violation sources beyond the standard model(SM).With the large number of quantum entangled h...The study of the charge conjugation and parity(CP)violation of hyperon is the precision frontier for probing possible new CP violation sources beyond the standard model(SM).With the large number of quantum entangled hyperonantihyperon pairs to be produced at Super Tau-Charm Facility(STCF),the CP asymmetry of hyperon is expected to be tested with a statistical sensitivity of 10^(−4) or even better.To cope with the statistical precision,the systematic effects from various aspects are critical and need to be studied in detail.In this paper,the sensitivity effects on the CP violation parameters associated with the detector resolution,including those of the position and momentum,are studied and discussed in detail.The results provide valuable guidance for the design of STCF detector.展开更多
For segmented detectors,surface flatness is critical as it directly influences both energy resolution and image clarity.Additionally,the limited adjustment range of the segmented detectors necessitates precise benchma...For segmented detectors,surface flatness is critical as it directly influences both energy resolution and image clarity.Additionally,the limited adjustment range of the segmented detectors necessitates precise benchmark construction.This paper proposes an architecture for detecting detector flatness based on channel spectral dispersion.By measuring the dispersion fringes for coplanar adjustment,the final adjustment residual is improved to better than 300 nm.This result validates the feasibility of the proposed technology and provides significant technical support for the development of next-generation large-aperture sky survey equipment.展开更多
Radiation doses to patients in diagnostics and interventional radiology need to be optimized to comply with the principles of radiation protection in medical practice. This involves using specific detectors with respe...Radiation doses to patients in diagnostics and interventional radiology need to be optimized to comply with the principles of radiation protection in medical practice. This involves using specific detectors with respective diagnostic beams to carry out quality control/quality assurance tests needed to optimize patient doses in the hospital. Semiconductor detectors are used in dosimetry to verify the equipment performance and dose to patients. This work aims to assess the performance, energy dependence, and response of five commercially available semiconductor detectors in RQR, RQR-M, RQA, and RQT at Secondary Standard Dosimetry for clinical applications. The diagnostic beams were generated using Exradin A4 reference ion chamber and PTW electrometer. The ambient temperature and pressure were noted for KTP correction. The detectors designed for RQR showed good performance in RQT beams and vice versa. The detectors designed for RQR-M displayed high energy dependency in other diagnostic beams. The type of diagnostic beam quality determines the response of semiconductor detectors. Therefore, a detector should be calibrated according to the beam qualities to be measured.展开更多
The polarization properties of light are widely applied in imaging,communications,materials analy⁃sis,and life sciences.Various methods have been developed that can measure the polarization information of a target.How...The polarization properties of light are widely applied in imaging,communications,materials analy⁃sis,and life sciences.Various methods have been developed that can measure the polarization information of a target.However,conventional polarization detection systems are often bulky and complex,limiting their poten⁃tial for broader applications.To address the challenges of miniaturization,integrated polarization detectors have been extensively explored in recent years,achieving significant advancements in performance and functionality.In this review,we focus mainly on integrated polarization detectors with innovative features,including infinitely high polarization discrimination,ultrahigh sensitivity to polarization state change,full Stokes parameters measure⁃ment,and simultaneous perception of polarization and other key properties of light.Lastly,we discuss the oppor⁃tunities and challenges for the future development of integrated polarization photodetectors.展开更多
Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency...Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency, high position resolution,and large-area splicing, and can well meet the requirement of large area neutron detection for neutron diffractometers. An engineering detector prototype based on a ~6LiF/ZnS(Ag) scintillation screen and SiPM array readout was fabricated for the General Purpose Powder Diffractometer of China Spallation Neutron Source(CSNS). The detector has an active area of 196 mm × 444 mm, with a pixel size of 4 mm × 4 mm. The key performances of the detector prototype were tested at the BL20 neutron beam line of CSNS. The test results show that the neutron detection efficiency of the detector was 32% and 42% at wavelengths of 1.4 ? and 2.8 ?, respectively. An interpolated neutron detection efficiency of 40.2% at a wavelength of 2 ? was obtained. The tested neutron efficiency non-uniformity of the detector was 10.2%, which is less than one-half that of the current general purpose powder diffractometer scintillator neutron detectors at CSNS. This work achieves, for the first time, an efficiency uniformity of < 11% in large-area mosaic neutron detectors, alongside significant advancements in electromagnetic interference immunity and cost-effectiveness.展开更多
The measurement of low-level radioactivity using high-purity germanium(HPGe)detectors is important in applications such as environmental background radiation,material screening,and rare decays.The dead layers,dead zon...The measurement of low-level radioactivity using high-purity germanium(HPGe)detectors is important in applications such as environmental background radiation,material screening,and rare decays.The dead layers,dead zones,aluminum shell thickness,and diameter of Ge crystals are the most influential factors affecting the performance of HPGe detectors;hence,precise modeling of the physical conditions of the detectors is highly desirable.In this study,the GEANT4 simulation framework with an optimized detector geometry adequately replicated the experimentally recorded spectrum.These detector simulations explored the idea of realizing a dead zone(an inactive volume)at the backend of an n-type coaxial Gecrystal.Using multigamma sources,the effect of true coincidence summing(TCS)on the full energy peak(FEP)efficiency calibration of an HPGe detector was investigated as a function of sample-to-detector distance.Good agreements between the simulated and experimental efficiencies as well as the simulated and analytically calculated summing coincidence correction coefficients were achieved.At a short distance between the source and detector,calculating the correction factors for a strong source posed challenges owing to significant deadtime and pile-up effects of the detection system.The described methodology can efficiently determine summing peak probabilities at short sample-to-detector distances.展开更多
A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nu...A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nuclei.The digital data acquisition system enables precise synchronization and processing of complex signals from various detectors,such as plastic scintillators,silicon detectors,and germaniumγdetectors.The system's performance was evaluated using theβdecay of^(32)Ar and its neighboring nuclei,produced via projectile fragmentation at the first Radioactive Ion Beam Line in Lanzhou(RIBLL1).Key measurements,including the half-life,charged-particle spectrum,andγ-ray spectrum,were obtained and compared with previous results for validation.Using the implantation–decay method,the isotopes of interest were implanted into two doublesided silicon strip detectors,where their subsequent decays were measured and correlated with preceding implantations using both position and time information.This detection system has potential for further applications,including the study ofβ-delayed charged-particle decay and direct proton emissions from even more exotic proton-rich nuclei.展开更多
基金supported by National Key R&D grant from the Ministry of Science and Technology of China(Nos.2021YFA1601600,2023YFA1606200)National Science Foundation of China(Nos.12090062,12105008)the Major State Basic Research Development Program of China.
文摘We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.
基金supports from the National Natural Science Foundation of China(22375220,U2001214,22471302)the Guangdong Basic and Applied Basic Research Foundation(2024B1515020101)Open Project Fund from State Key Laboratory of Optoelectronic Materials and Technologies(OEMT-2024-KF-08).
文摘Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.
基金supported by the NSFC under Grant No.62474169the National Key Research and Development Program of China under Grant No.2024YFB3212200the funding from USTC under Grant Nos.WK2100000025,KY2190000003,and KY2190000006。
文摘Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.
基金Supported by the National Natural Science Foundation of China under Grant Nos U0934001 and 11076028the Science and Technology Commission of Shanghai Municipality under Grant Nos 11DZ1140202 and 13XD1425400the Pudong New Area Science and Technology Development Fund of China under Grant No PKJ2012-D04
文摘A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the phase difference between the Rayleigh scattering from two sections of the fiber. A new demodulation method called the inverse transmission matrix demodulation scheme is utilized to demodulate the distributed phase from the backward scattering along the long fiber, The experimental results show that the 120°-phase-difference inter- ferometer φ-OTDR can detect the phase along the 3km fiber, and the acoustic signal within the whole human hearing range of 20 Hz-20 kHz is reproduced accurately and quickly.
基金Project partially supported by the National Natural Science Foundation of China (Grant Nos 10527003 and 60672104)the State Key Development Program for Basic Research of China (Grant No 2006CB705700-05)+1 种基金Joint Research Foundation of Beijing Education Committee (Grant No SYS100010401)Beijing Natural Science Foundation (Grant No 3073019)
文摘Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short scan time, phase errors, especially spatially-dependent phase shift, caused by a variety of factors may result in misplacement of fat and water voxels. In this paper, a novel phase correction algorithm was used to calibrate those phase errors during image reconstruction. This algorithm corrects phase by region growing, employing both the magnitude and the phase information of image pixels. Phantom and in vivo imagings were performed to validate the technique. As a result, excellent fat-suppressed images were acquired by using single-acquisition phase-sensitive SSFP with phase correction.
基金Supported by Haikou Key Science and Technology Project (2012-075)Haikou Science and Technology Planning Project(2009-049-1)Science and Technology Fund of Haikou Health Bureau(2010-SWY-13-058)
文摘Objective:Late gadolinium enhancement(LGE) patterns of cardiovascular magnetic resonance (CMR) relying on PSIR(phase-sensitive inversion recovery sequence) techniques had been used to determine the characteristics of LGE in apical hypertrophic cardiomyopathy(ApHCM). Methods:Forty patients pure ApHCM[age,(60.2±10.4) years,31 men]were enrolled.LGE images were acquired using PSIR,and analyzed using a 17-segment model.Summing the LGE areas in all short axis slices yielded the total volume of late enhancement,which was subsequently presented as a proportion of total LV myocardium(%LGE).Results:Mean maximal apical wall thickness was(17.9±2.3) mm,and mean left ventricular(LV) ejection fraction was(67.7±8.0)%.LGE was detected in 130 segments of 30 patients(75.0%),occupying(4.9±5.5)% of LV myocardium.LGE was mainly detected at the junction between left and right ventricles in 12(30%) and at the apex in 28(70%),although LGE-positive areas were widely distributed,and not limited to the apex.Focal LGE at the non-hypertrophic LV segments was found in some ApHCM patients,even without LGE of hypertrophied apical segments.Conclusions:LGE was frequently observed not only in the thickened apex of the heart but also in other LV segments,irrespective of the presence or absence of hypertrophy.The simple presence of LGE on CMR was not representative of adverse prognosis in this population.
基金supported by Haikou Key Science and Technology Project (2012-075)Haikou Science and Technology Planning Project(2009-049-1)Science and Technology Fund of Haikou Health Bureau(2010-SWY-13-058)
文摘Objective:To determine the deference between phase sensitive magnetic resonance(MR) imaging and magnitude reconstruction to detect infracted myocardium.Methods:Twenty patients(16 men;4 women;mean age,56 years),experienced Q-wave myocardial infarction 2 weeks earlier were examined with a 3.0-T MR system 10 minutes after administration of 0.1 mmol/kg body weight gadobenate dimeglumine.To determine the optimal TI,a TI scout sequence was used.A segmented 2D IR true fast imaging with steady-state precession(trueFISP) sequence that produces both phase-sensitive and magnitude-reconstructed images were used at TI values of 200-600 msec(TI values were varied in 100-msec steps) and at optimal TI(mean value,330 msec).Contrast- noise ratios(CNRs) of normal and infarcted myocardium and the area of infarcted myocardium were determined.Two-tailed unpaired sample Student t test was used to compare CNRs,and area of infarction.Results:MMean CNR phase-sensitive and magnitude-reconstructed images at optimal TI(mean value,330 msec) were 6.2,and 6.1,respectively.For a TI of 200 msec,CNR values were 5.5,and 4.2,respectively;for TI of 600 msec,CNR values were 5.8 and 4.3,respectively.Area of infarcted myocardium was underestimated on magnitude-reconstruction images(P = 0.002-0.03) for short TI values(ie.,200 msec) but not on phase sensitive reconstructed when compared with IR tureFISP images obtained at optimal TI.Conclusions: LPhase-sensitive image reconstruction results in reduced need for precise choice of TI and more consistent image quality.
基金Project supported by the National Natural Science Foundation of China(Grant Nos60308002and60678005)the Foundation for the Author of National Excellent Doctoral Dissertation of China(Grant No200339)+2 种基金the Foundation for Key Program of Ministry of Education,China(Grant No105156)the Fok Ying-Tong Education Foundation for Young Teachers in the Higher Education Institutions of China(Grant No101061)the Specialized Research Fund for the Doctoral Program of Higher Education of China(Grant No20050698017)
文摘We study the colour-locked twin-noisy-field correlation effects in the fifth-order nonlinear susceptibility of ultrafast polarization beats in a cascade four-level system. More importantly, the fifth-order phase-sensitive heterodyne detection of ultrafast polarization beats has been exploited. The fifth-order nonlinear optical response can be controlled and modified through the colour-locked correlation of twin noisy fields. Thus, this method with the phase dispersion information is a good way to measure the real and imaginary parts of the fifth-order nonlinear susceptibility.
基金Project supported by National Natural Science Foundation of China(Grant Nos.11704053 and 52175531)the Science and Technology Research Program of Chongqing Municipal Education Commission(Grant No.KJQN201800629)。
文摘We present a theoretical scheme for broadband multi-channel quantum noise suppression and phase-sensitive modulation of continuous variables in a coupled resonant system with quantum entanglement properties.The effects of different coupling strengths,pumping power in suppressing quantum noise and controlling the width of quantum interference channels are analyzed carefully.Furthermore,quantum noise suppression at quadrature amplitude is obtained with phase-sensitive modulation.It shows that the entanglement strength of the output field and the quantum noise suppression effect can be enhanced significantly by a strong pumping filed due to interaction of pumping light with the nonlinear crystal.The full width at half maxima(FWHM)of the noise curve at the resonant peak(△=0 MHz)is broadened up to 2.17 times compared to the single cavity.In the strong coupling resonant system,the FWHM at △=0 MHz(△=±3.1 MHz)is also broadened up to 1.27(3.53)times compared to the weak coupling resonant system case.The multi-channel quantum interference creates an electromagnetically induced transparent-like line shape,which can be used to improve the transmission efficiency and stability of wave packets in quantum information processing and quantum memory.
基金supported by the National Natural Science Foundation of China(No.12235006)the National Key Research and Development Program of China(No.2020YFE0202002.
文摘X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors.
基金supported by the National Natural Science Foundation of China(12125505).
文摘The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process that leads to a significant deterioration of non-uniformity when scaling up to larger areas.Since the performance of gaseous detectors is highly dependent on the choice of working gas,optimizing the gas mixture offers a promising solution to improve the uniformity performance.This paper addresses these challenges through a combined approach of simulation based on Garfield++and experimental studies.The simulation investigates the properties of different mixing fractions of gas mixtures and their impact on detector performance,including gain uniformity and time resolution.To verify the simulation results,experimental tests were conducted using a multi-channel PICOSEC MM prototype with different gas mixtures.The experimental results are consistent with the findings of the simulation,indicating that a higher concentration of neon significantly improves the detector’s gain uniformity.Furthermore,the influence of gas mixtures on time resolution was explored as a critical performance indicator.The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance.
文摘To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the glass-metal hetero-bonding process.This study focuses on the analysis and experimental re-search of the bonding layer in the integrated structure.By optimizing the structural configuration and select-ing suitable bonding processes,the reliability of the telescope system is enhanced.The research indicates that using J-133 adhesive achieves the best performance,with a bonding layer thickness of 0.30 mm and a metal substrate surface roughness of Ra 0.8.These findings significantly enhance the reliability of the optical sys-tem while minimizing potential risks.
基金supported by the National Key R&D Program of China(2022YFA1602200)the International Partnership Program of the Chinese Academy of Sciences(211134KYSB20200057).
文摘The study of the charge conjugation and parity(CP)violation of hyperon is the precision frontier for probing possible new CP violation sources beyond the standard model(SM).With the large number of quantum entangled hyperonantihyperon pairs to be produced at Super Tau-Charm Facility(STCF),the CP asymmetry of hyperon is expected to be tested with a statistical sensitivity of 10^(−4) or even better.To cope with the statistical precision,the systematic effects from various aspects are critical and need to be studied in detail.In this paper,the sensitivity effects on the CP violation parameters associated with the detector resolution,including those of the position and momentum,are studied and discussed in detail.The results provide valuable guidance for the design of STCF detector.
文摘For segmented detectors,surface flatness is critical as it directly influences both energy resolution and image clarity.Additionally,the limited adjustment range of the segmented detectors necessitates precise benchmark construction.This paper proposes an architecture for detecting detector flatness based on channel spectral dispersion.By measuring the dispersion fringes for coplanar adjustment,the final adjustment residual is improved to better than 300 nm.This result validates the feasibility of the proposed technology and provides significant technical support for the development of next-generation large-aperture sky survey equipment.
文摘Radiation doses to patients in diagnostics and interventional radiology need to be optimized to comply with the principles of radiation protection in medical practice. This involves using specific detectors with respective diagnostic beams to carry out quality control/quality assurance tests needed to optimize patient doses in the hospital. Semiconductor detectors are used in dosimetry to verify the equipment performance and dose to patients. This work aims to assess the performance, energy dependence, and response of five commercially available semiconductor detectors in RQR, RQR-M, RQA, and RQT at Secondary Standard Dosimetry for clinical applications. The diagnostic beams were generated using Exradin A4 reference ion chamber and PTW electrometer. The ambient temperature and pressure were noted for KTP correction. The detectors designed for RQR showed good performance in RQT beams and vice versa. The detectors designed for RQR-M displayed high energy dependency in other diagnostic beams. The type of diagnostic beam quality determines the response of semiconductor detectors. Therefore, a detector should be calibrated according to the beam qualities to be measured.
基金Supported by the National Key Research and Development Program of China(2022YFA1404602)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDB0580000)+3 种基金the National Natural Science Foundation of China(U23B2045,62305362)the Program of Shanghai Academic/Technology Research Leader(22XD1424400)the Fund of SITP Innovation Foundation(CX-461 and CX-522)Special Project to Seize the Commanding Heights of Science and Technology of Chinese Academy of Sciences,subtopic(GJ0090406-6).
文摘The polarization properties of light are widely applied in imaging,communications,materials analy⁃sis,and life sciences.Various methods have been developed that can measure the polarization information of a target.However,conventional polarization detection systems are often bulky and complex,limiting their poten⁃tial for broader applications.To address the challenges of miniaturization,integrated polarization detectors have been extensively explored in recent years,achieving significant advancements in performance and functionality.In this review,we focus mainly on integrated polarization detectors with innovative features,including infinitely high polarization discrimination,ultrahigh sensitivity to polarization state change,full Stokes parameters measure⁃ment,and simultaneous perception of polarization and other key properties of light.Lastly,we discuss the oppor⁃tunities and challenges for the future development of integrated polarization photodetectors.
基金Project supported by the National Natural Science Foundation of China (Grant No. 12275181)Guangdong Basic and Applied Basic Research Foundation (Grant No. 2022B1515120071)+1 种基金Promotion Project of Scientific Research Capability of Key Construction Disciplines in Guangdong Province (Grant No. 2022ZDJS118)Natural Science Foundation of Top Talent SZTU (Grant No. GDRC202205)。
文摘Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency, high position resolution,and large-area splicing, and can well meet the requirement of large area neutron detection for neutron diffractometers. An engineering detector prototype based on a ~6LiF/ZnS(Ag) scintillation screen and SiPM array readout was fabricated for the General Purpose Powder Diffractometer of China Spallation Neutron Source(CSNS). The detector has an active area of 196 mm × 444 mm, with a pixel size of 4 mm × 4 mm. The key performances of the detector prototype were tested at the BL20 neutron beam line of CSNS. The test results show that the neutron detection efficiency of the detector was 32% and 42% at wavelengths of 1.4 ? and 2.8 ?, respectively. An interpolated neutron detection efficiency of 40.2% at a wavelength of 2 ? was obtained. The tested neutron efficiency non-uniformity of the detector was 10.2%, which is less than one-half that of the current general purpose powder diffractometer scintillator neutron detectors at CSNS. This work achieves, for the first time, an efficiency uniformity of < 11% in large-area mosaic neutron detectors, alongside significant advancements in electromagnetic interference immunity and cost-effectiveness.
基金supported by the Natural Science Foundation of Gansu Province(No.22JR5RA118)the National Natural Science Foundation of China(Nos.12121005 and U1932138)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB34010000)。
文摘The measurement of low-level radioactivity using high-purity germanium(HPGe)detectors is important in applications such as environmental background radiation,material screening,and rare decays.The dead layers,dead zones,aluminum shell thickness,and diameter of Ge crystals are the most influential factors affecting the performance of HPGe detectors;hence,precise modeling of the physical conditions of the detectors is highly desirable.In this study,the GEANT4 simulation framework with an optimized detector geometry adequately replicated the experimentally recorded spectrum.These detector simulations explored the idea of realizing a dead zone(an inactive volume)at the backend of an n-type coaxial Gecrystal.Using multigamma sources,the effect of true coincidence summing(TCS)on the full energy peak(FEP)efficiency calibration of an HPGe detector was investigated as a function of sample-to-detector distance.Good agreements between the simulated and experimental efficiencies as well as the simulated and analytically calculated summing coincidence correction coefficients were achieved.At a short distance between the source and detector,calculating the correction factors for a strong source posed challenges owing to significant deadtime and pile-up effects of the detection system.The described methodology can efficiently determine summing peak probabilities at short sample-to-detector distances.
基金supported by the National Key Research and Development Project,China(No.2023YFA1606404)the Strategic Priority Research Program of Chinese Academy of Sciences(No.XDB34010300)+5 种基金the National Natural Science Foundation of China(Nos.12022501,12105329,12475127)the Guangdong Major Project of Basic and Applied Basic Research(No.2021B0301030006)the Research Program of Heavy Ion Science and Technology Key Laboratory,Institute of Modern Physics,Chinese Academy of Sciences(Nos.HIST2024KS04,HIST2024CO04)Longyuan Youth Innovation and Entrepreneurship Talent Project of Gansu Province(No.2024GZT04)State Key Laboratory of Nuclear Physics and Technology,Peking University(No.NPT2023KFY01)the Major Science and Technology Projects in Gansu Province(No.24GD13GA005)。
文摘A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nuclei.The digital data acquisition system enables precise synchronization and processing of complex signals from various detectors,such as plastic scintillators,silicon detectors,and germaniumγdetectors.The system's performance was evaluated using theβdecay of^(32)Ar and its neighboring nuclei,produced via projectile fragmentation at the first Radioactive Ion Beam Line in Lanzhou(RIBLL1).Key measurements,including the half-life,charged-particle spectrum,andγ-ray spectrum,were obtained and compared with previous results for validation.Using the implantation–decay method,the isotopes of interest were implanted into two doublesided silicon strip detectors,where their subsequent decays were measured and correlated with preceding implantations using both position and time information.This detection system has potential for further applications,including the study ofβ-delayed charged-particle decay and direct proton emissions from even more exotic proton-rich nuclei.