期刊文献+
共找到21,813篇文章
< 1 2 250 >
每页显示 20 50 100
Preparation and measurement of an^(37)Ar source for liquid xenon detector calibration
1
作者 Xu‑Nan Guo Chang Cai +8 位作者 Fei Gao Yang Lei Kai‑Hang Li Chun‑Lei Su Ze‑Peng Wu Xiang Xiao Ling‑Feng Xie Yi‑Fei Zhao Xiao‑Peng Zhou 《Nuclear Science and Techniques》 2026年第1期202-211,共10页
We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-... We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors. 展开更多
关键词 ^(37)Ar Gaseous xenon detector LOW-ENERGY Calibration source
在线阅读 下载PDF
Lattice Anchoring Stabilizesα-FAPbI_(3) Perovskite for High-Performance X-Ray Detectors
2
作者 Yu-Hua Huang Su-Yan Zou +5 位作者 Cong-Yi Sheng Yu-Chuang Fang Xu-Dong Wang Wei Wei Wen-Guang Li Dai-Bin Kuang 《Nano-Micro Letters》 2026年第1期337-354,共18页
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl... Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses. 展开更多
关键词 α-FAPbI_(3)perovskite Conjugated organic cation Lattice anchoring Phase stability X-ray detectors
在线阅读 下载PDF
Ultralow dark current soft X-ray detectors based on lead-free double perovskite Cs_(2)AgBiBr_(6)
3
作者 Long Cheng Lijuan Huang +15 位作者 Mulin Sun Ying Meng Yuan Li Tianyu Liu Pengju Tan Mingzhu Hu Huaqing Yang Xiaolan Ma Shunjie Yu Xiaohu Hou Yong Guan Junfa Zhu Xiaosong Liu Yu Li Shibing Long Qin Hu 《Journal of Semiconductors》 2026年第1期109-116,共8页
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi... Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors. 展开更多
关键词 soft X-ray detector lead-free double perovskite Cs_(2)AgBiBr_(6) ALLOYING IMAGING
在线阅读 下载PDF
Phase-Sensitive Optical Time-Domain Reflectometer Based on a 120°-Phase-Difference Michelson Interferometer 被引量:2
4
作者 曹玉龙 杨飞 +3 位作者 徐丹 叶青 蔡海文 方祖捷 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第5期22-25,共4页
A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the ... A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the phase difference between the Rayleigh scattering from two sections of the fiber. A new demodulation method called the inverse transmission matrix demodulation scheme is utilized to demodulate the distributed phase from the backward scattering along the long fiber, The experimental results show that the 120°-phase-difference inter- ferometer φ-OTDR can detect the phase along the 3km fiber, and the acoustic signal within the whole human hearing range of 20 Hz-20 kHz is reproduced accurately and quickly. 展开更多
关键词 of is Phase-Difference Michelson Interferometer phase-sensitive Optical Time-Domain Reflectometer Based on a 120 on into kHz EDFA with be that
原文传递
Phase-sensitive fat suppression steady-state free procession sequence with phase correction 被引量:1
5
作者 俎中良 周堃 +2 位作者 张仕刚 高篙 包尚联 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第1期328-334,共7页
Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short ... Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short scan time, phase errors, especially spatially-dependent phase shift, caused by a variety of factors may result in misplacement of fat and water voxels. In this paper, a novel phase correction algorithm was used to calibrate those phase errors during image reconstruction. This algorithm corrects phase by region growing, employing both the magnitude and the phase information of image pixels. Phantom and in vivo imagings were performed to validate the technique. As a result, excellent fat-suppressed images were acquired by using single-acquisition phase-sensitive SSFP with phase correction. 展开更多
关键词 steady-state free precession fat suppression phase-sensitive phase correction
原文传递
Delay enhancement patterns in apical hypertrophic cardiomyopathy by phase-sensitive inversion recovery sequence 被引量:1
6
作者 Zi-Yi Guo Jing Chen +6 位作者 Qi-Zhou Liang Hai-Yan Liao Shui-Xi Fu Qian-Yu Tang Cai-Xiang Chen Xiang-Jun Han Feng Gao 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2012年第10期828-830,共3页
Objective:Late gadolinium enhancement(LGE) patterns of cardiovascular magnetic resonance (CMR) relying on PSIR(phase-sensitive inversion recovery sequence) techniques had been used to determine the characteristics of ... Objective:Late gadolinium enhancement(LGE) patterns of cardiovascular magnetic resonance (CMR) relying on PSIR(phase-sensitive inversion recovery sequence) techniques had been used to determine the characteristics of LGE in apical hypertrophic cardiomyopathy(ApHCM). Methods:Forty patients pure ApHCM[age,(60.2±10.4) years,31 men]were enrolled.LGE images were acquired using PSIR,and analyzed using a 17-segment model.Summing the LGE areas in all short axis slices yielded the total volume of late enhancement,which was subsequently presented as a proportion of total LV myocardium(%LGE).Results:Mean maximal apical wall thickness was(17.9±2.3) mm,and mean left ventricular(LV) ejection fraction was(67.7±8.0)%.LGE was detected in 130 segments of 30 patients(75.0%),occupying(4.9±5.5)% of LV myocardium.LGE was mainly detected at the junction between left and right ventricles in 12(30%) and at the apex in 28(70%),although LGE-positive areas were widely distributed,and not limited to the apex.Focal LGE at the non-hypertrophic LV segments was found in some ApHCM patients,even without LGE of hypertrophied apical segments.Conclusions:LGE was frequently observed not only in the thickened apex of the heart but also in other LV segments,irrespective of the presence or absence of hypertrophy.The simple presence of LGE on CMR was not representative of adverse prognosis in this population. 展开更多
关键词 APICAL HYPERTROPHIC cardiomyopathy Cardiovascular magnetic resonance Late gadolinium ENHANCEMENT phase-sensitive inversion recovery SEQUENCE
暂未订购
Comparison between magnitude reconstruction and phase-sensitive mR imaging in the detection of myocardial infarction
7
作者 Zi-Yi Guo Jing Chen +6 位作者 Qi-Zhou Liang Hai-Yan Liao Shui-Xi Fu Qian-Yu Tang Cai-Xiang Chen Xiang-Jun Han Feng Gao 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2012年第11期911-913,共3页
Objective:To determine the deference between phase sensitive magnetic resonance(MR) imaging and magnitude reconstruction to detect infracted myocardium.Methods:Twenty patients(16 men;4 women;mean age,56 years),experie... Objective:To determine the deference between phase sensitive magnetic resonance(MR) imaging and magnitude reconstruction to detect infracted myocardium.Methods:Twenty patients(16 men;4 women;mean age,56 years),experienced Q-wave myocardial infarction 2 weeks earlier were examined with a 3.0-T MR system 10 minutes after administration of 0.1 mmol/kg body weight gadobenate dimeglumine.To determine the optimal TI,a TI scout sequence was used.A segmented 2D IR true fast imaging with steady-state precession(trueFISP) sequence that produces both phase-sensitive and magnitude-reconstructed images were used at TI values of 200-600 msec(TI values were varied in 100-msec steps) and at optimal TI(mean value,330 msec).Contrast- noise ratios(CNRs) of normal and infarcted myocardium and the area of infarcted myocardium were determined.Two-tailed unpaired sample Student t test was used to compare CNRs,and area of infarction.Results:MMean CNR phase-sensitive and magnitude-reconstructed images at optimal TI(mean value,330 msec) were 6.2,and 6.1,respectively.For a TI of 200 msec,CNR values were 5.5,and 4.2,respectively;for TI of 600 msec,CNR values were 5.8 and 4.3,respectively.Area of infarcted myocardium was underestimated on magnitude-reconstruction images(P = 0.002-0.03) for short TI values(ie.,200 msec) but not on phase sensitive reconstructed when compared with IR tureFISP images obtained at optimal TI.Conclusions: LPhase-sensitive image reconstruction results in reduced need for precise choice of TI and more consistent image quality. 展开更多
关键词 phase-sensitive image RECONSTRUCTION MAGNITUDE reconstruct Infracted myocardium CNR
在线阅读 下载PDF
Fifth-order phase-sensitive detection of ultrafast polarization beats in cascade four-level system
8
作者 聂志强 李沛哲 +8 位作者 余孝军 张彦鹏 姜彤 李岭 甘琛利 左翠翠 张鹏飞 宋建平 卢克清 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第3期978-987,共10页
We study the colour-locked twin-noisy-field correlation effects in the fifth-order nonlinear susceptibility of ultrafast polarization beats in a cascade four-level system. More importantly, the fifth-order phase-sensi... We study the colour-locked twin-noisy-field correlation effects in the fifth-order nonlinear susceptibility of ultrafast polarization beats in a cascade four-level system. More importantly, the fifth-order phase-sensitive heterodyne detection of ultrafast polarization beats has been exploited. The fifth-order nonlinear optical response can be controlled and modified through the colour-locked correlation of twin noisy fields. Thus, this method with the phase dispersion information is a good way to measure the real and imaginary parts of the fifth-order nonlinear susceptibility. 展开更多
关键词 ultrafast polarization beat nonlinear susceptibility phase-sensitive detection
原文传递
Broadband multi-channel quantum noise suppression and phase-sensitive modulation based on entangled beam
9
作者 邸克 谈帅 +2 位作者 程安宇 刘宇 杜佳佳 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期191-198,共8页
We present a theoretical scheme for broadband multi-channel quantum noise suppression and phase-sensitive modulation of continuous variables in a coupled resonant system with quantum entanglement properties.The effect... We present a theoretical scheme for broadband multi-channel quantum noise suppression and phase-sensitive modulation of continuous variables in a coupled resonant system with quantum entanglement properties.The effects of different coupling strengths,pumping power in suppressing quantum noise and controlling the width of quantum interference channels are analyzed carefully.Furthermore,quantum noise suppression at quadrature amplitude is obtained with phase-sensitive modulation.It shows that the entanglement strength of the output field and the quantum noise suppression effect can be enhanced significantly by a strong pumping filed due to interaction of pumping light with the nonlinear crystal.The full width at half maxima(FWHM)of the noise curve at the resonant peak(△=0 MHz)is broadened up to 2.17 times compared to the single cavity.In the strong coupling resonant system,the FWHM at △=0 MHz(△=±3.1 MHz)is also broadened up to 1.27(3.53)times compared to the weak coupling resonant system case.The multi-channel quantum interference creates an electromagnetically induced transparent-like line shape,which can be used to improve the transmission efficiency and stability of wave packets in quantum information processing and quantum memory. 展开更多
关键词 quantum entanglement broadband quantum interference phase-sensitive modulation
原文传递
RAA-DETECTOR布鲁氏菌核酸快速检测方法的建立及应用
10
作者 张雲龙 王靖雷 +8 位作者 朱亚杰 张明洁 康澳 周翔 魏凯 曹洪防 李强 王勇 苏峰 《畜牧兽医学报》 北大核心 2025年第10期5115-5124,共10页
本研究旨在建立不依赖于专业设备的布鲁氏菌病高效快速检测体系,实现临床样本40 min内快速检测。首先比对不同布鲁氏菌的基因组,找到布鲁氏菌的核心共有序列,以布鲁氏菌S2菌株基因SEQ NO.6(CN 105018489A)为模板构建阳性质粒,用于后续试... 本研究旨在建立不依赖于专业设备的布鲁氏菌病高效快速检测体系,实现临床样本40 min内快速检测。首先比对不同布鲁氏菌的基因组,找到布鲁氏菌的核心共有序列,以布鲁氏菌S2菌株基因SEQ NO.6(CN 105018489A)为模板构建阳性质粒,用于后续试验;通过原核表达的方法分别表达CRISPR/AsCas12a和LwaCas13a蛋白;通过重组酶介导的等温核酸扩增技术(RAA)、体外表达技术结合AsCas12a/LwaCas13a的DETECTOR系统,优化高效检测体系、通过无限稀释法等进行检测。结果发现,设计的RAA引物能够有效扩增样本中的DNA片段,DETECTOR得到最佳反应的AsCas12a浓度为200 nmol·L^(-1),gRNA为200 nmol·L^(-1);Cas13a浓度为300 nmol·L^(-1),crRNA浓度为400 nmol·L^(-1);RAA-AsCas12a和RAA-LwaCas13a的检测体系的最佳反应时间为35 min,侧平流式纸条的最佳检测时间为20 min,细菌最低检测浓度为10 Copies·μL^(-1),且具有较好的检测特异性,临床样本的检测试验表明两种方法均有较好的重复性和检测精度,但LwaCas13a的精测精度更高,但二者无显著差异。该研究建立了2种RAA-CRISPR/Cas布鲁氏菌核酸快速检测体系,在临床上可获得较好的应用,RAA-LwaCas13a的检测方法精度更高。 展开更多
关键词 布鲁氏菌 RAA detector系统 SHERLOCK系统 AsCas12a LwaLwaCas13a
在线阅读 下载PDF
CMOS direct conversion X-ray detector coupled with fluorinated liquid 被引量:1
11
作者 Shi-Hua Liu Chao-Song Gao +5 位作者 Xin Zhang Xiang-Ming Sun Meng Wu Zhi-Hui Han Tong Wan Yong-Shuai Ge 《Nuclear Science and Techniques》 2025年第1期59-68,共10页
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho... X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors. 展开更多
关键词 FC40 electronic fluorinated liquid CMOS pixel chip X-ray detector Spatial resolution
在线阅读 下载PDF
Optimizing neon-based gas mixtures for two-stage amplification fast-timing Micromegas detectors
12
作者 Yue Meng Xu Wang +3 位作者 Jianbei Liu Ming Shao Zhiyong Zhang Yi Zhou 《中国科学技术大学学报》 北大核心 2025年第4期59-66,58,I0002,共10页
The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process th... The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process that leads to a significant deterioration of non-uniformity when scaling up to larger areas.Since the performance of gaseous detectors is highly dependent on the choice of working gas,optimizing the gas mixture offers a promising solution to improve the uniformity performance.This paper addresses these challenges through a combined approach of simulation based on Garfield++and experimental studies.The simulation investigates the properties of different mixing fractions of gas mixtures and their impact on detector performance,including gain uniformity and time resolution.To verify the simulation results,experimental tests were conducted using a multi-channel PICOSEC MM prototype with different gas mixtures.The experimental results are consistent with the findings of the simulation,indicating that a higher concentration of neon significantly improves the detector’s gain uniformity.Furthermore,the influence of gas mixtures on time resolution was explored as a critical performance indicator.The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance. 展开更多
关键词 gaseous detectors MICROMEGAS timing detectors fast-timing Micromegas Monte Carlo simulation gain uniformity
在线阅读 下载PDF
Study of bonding layer for integrated structure of space gravitational wave detector telescope
13
作者 ZHAO Hong-chao LIU Chang +2 位作者 ZHOU Wen-ke ZHU Han-bin CHEN Wen-duo 《中国光学(中英文)》 北大核心 2025年第3期715-724,共10页
To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the... To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the glass-metal hetero-bonding process.This study focuses on the analysis and experimental re-search of the bonding layer in the integrated structure.By optimizing the structural configuration and select-ing suitable bonding processes,the reliability of the telescope system is enhanced.The research indicates that using J-133 adhesive achieves the best performance,with a bonding layer thickness of 0.30 mm and a metal substrate surface roughness of Ra 0.8.These findings significantly enhance the reliability of the optical sys-tem while minimizing potential risks. 展开更多
关键词 space gravitational-wave detector integrated structure glass-metal hetero-bonding
在线阅读 下载PDF
Unbiased test of the hyperon CP violation in terms of detector resolution at STCF
14
作者 Ming Xu Liang Liu +2 位作者 Yupeng Pei Xiaorong Zhou Yingchun Zhu 《中国科学技术大学学报》 北大核心 2025年第4期41-47,40,I0002,共9页
The study of the charge conjugation and parity(CP)violation of hyperon is the precision frontier for probing possible new CP violation sources beyond the standard model(SM).With the large number of quantum entangled h... The study of the charge conjugation and parity(CP)violation of hyperon is the precision frontier for probing possible new CP violation sources beyond the standard model(SM).With the large number of quantum entangled hyperonantihyperon pairs to be produced at Super Tau-Charm Facility(STCF),the CP asymmetry of hyperon is expected to be tested with a statistical sensitivity of 10^(−4) or even better.To cope with the statistical precision,the systematic effects from various aspects are critical and need to be studied in detail.In this paper,the sensitivity effects on the CP violation parameters associated with the detector resolution,including those of the position and momentum,are studied and discussed in detail.The results provide valuable guidance for the design of STCF detector. 展开更多
关键词 BESIII experiment STCF hyperon CP violation detector resolution unbiased test
在线阅读 下载PDF
Flatness detection method of splicing detector based on channel spectral dispersion
15
作者 ZHAO Hong-chao ZHANG Xiao-qian AN Qi-chang 《中国光学(中英文)》 北大核心 2025年第4期889-898,共10页
For segmented detectors,surface flatness is critical as it directly influences both energy resolution and image clarity.Additionally,the limited adjustment range of the segmented detectors necessitates precise benchma... For segmented detectors,surface flatness is critical as it directly influences both energy resolution and image clarity.Additionally,the limited adjustment range of the segmented detectors necessitates precise benchmark construction.This paper proposes an architecture for detecting detector flatness based on channel spectral dispersion.By measuring the dispersion fringes for coplanar adjustment,the final adjustment residual is improved to better than 300 nm.This result validates the feasibility of the proposed technology and provides significant technical support for the development of next-generation large-aperture sky survey equipment. 展开更多
关键词 large aperture telescope segmented detector surface wavefront detection channel spectral dispersion
在线阅读 下载PDF
Performance Assessment of Semiconductor Detector Used in Diagnostics and Interventional Radiology at the Nigerian Secondary Standard Dosimetry Laboratory
16
作者 Samuel Mofolorunsho Oyeyemi Olumide Olaife Akerele +6 位作者 David Olakanmi Olaniyi Francis Adole Agada Sherif Olaniyi Kelani Akinkunmi Emmanuel Ladapo Ahmed Mohammed Shiyanbade Bamidele Musbau Adeniran Latifat Ronke Owoade 《World Journal of Nuclear Science and Technology》 2025年第1期17-29,共13页
Radiation doses to patients in diagnostics and interventional radiology need to be optimized to comply with the principles of radiation protection in medical practice. This involves using specific detectors with respe... Radiation doses to patients in diagnostics and interventional radiology need to be optimized to comply with the principles of radiation protection in medical practice. This involves using specific detectors with respective diagnostic beams to carry out quality control/quality assurance tests needed to optimize patient doses in the hospital. Semiconductor detectors are used in dosimetry to verify the equipment performance and dose to patients. This work aims to assess the performance, energy dependence, and response of five commercially available semiconductor detectors in RQR, RQR-M, RQA, and RQT at Secondary Standard Dosimetry for clinical applications. The diagnostic beams were generated using Exradin A4 reference ion chamber and PTW electrometer. The ambient temperature and pressure were noted for KTP correction. The detectors designed for RQR showed good performance in RQT beams and vice versa. The detectors designed for RQR-M displayed high energy dependency in other diagnostic beams. The type of diagnostic beam quality determines the response of semiconductor detectors. Therefore, a detector should be calibrated according to the beam qualities to be measured. 展开更多
关键词 Semiconductor detectors Optimization of Protection CALIBRATION Patient Dose Diagnostic Radiology
在线阅读 下载PDF
Advances in integrated polarization detectors with innovative features
17
作者 BU Yong-Hao ZHOU Jing +8 位作者 DENG Jie WANG Ruo-Wen YE Tao SHI Meng-Die HUANG Jun-Wei ZHANG Yu-Jie NING Jun LU Wei CHEN Xiao-Shuang 《红外与毫米波学报》 北大核心 2025年第3期371-383,共13页
The polarization properties of light are widely applied in imaging,communications,materials analy⁃sis,and life sciences.Various methods have been developed that can measure the polarization information of a target.How... The polarization properties of light are widely applied in imaging,communications,materials analy⁃sis,and life sciences.Various methods have been developed that can measure the polarization information of a target.However,conventional polarization detection systems are often bulky and complex,limiting their poten⁃tial for broader applications.To address the challenges of miniaturization,integrated polarization detectors have been extensively explored in recent years,achieving significant advancements in performance and functionality.In this review,we focus mainly on integrated polarization detectors with innovative features,including infinitely high polarization discrimination,ultrahigh sensitivity to polarization state change,full Stokes parameters measure⁃ment,and simultaneous perception of polarization and other key properties of light.Lastly,we discuss the oppor⁃tunities and challenges for the future development of integrated polarization photodetectors. 展开更多
关键词 integrated polarization detector infinite polarization extinction ratio polarization state change detection full-Stokes multidimensional detection
在线阅读 下载PDF
A large-area scintillation neutron detector based on WLSF and SiPM readout
18
作者 Xiao-Hu Wang Yang-Tu Lu +4 位作者 Bin Tang Xiu-Ku Wang Shao-Jia Chen Ze-Ren Li Zhi-Jia Sun 《Chinese Physics B》 2025年第6期192-197,共6页
Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency... Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency, high position resolution,and large-area splicing, and can well meet the requirement of large area neutron detection for neutron diffractometers. An engineering detector prototype based on a ~6LiF/ZnS(Ag) scintillation screen and SiPM array readout was fabricated for the General Purpose Powder Diffractometer of China Spallation Neutron Source(CSNS). The detector has an active area of 196 mm × 444 mm, with a pixel size of 4 mm × 4 mm. The key performances of the detector prototype were tested at the BL20 neutron beam line of CSNS. The test results show that the neutron detection efficiency of the detector was 32% and 42% at wavelengths of 1.4 ? and 2.8 ?, respectively. An interpolated neutron detection efficiency of 40.2% at a wavelength of 2 ? was obtained. The tested neutron efficiency non-uniformity of the detector was 10.2%, which is less than one-half that of the current general purpose powder diffractometer scintillator neutron detectors at CSNS. This work achieves, for the first time, an efficiency uniformity of < 11% in large-area mosaic neutron detectors, alongside significant advancements in electromagnetic interference immunity and cost-effectiveness. 展开更多
关键词 scintillation neutron detector silicon photomultiplier position sensitive neutron detector
原文传递
Study of true coincidence summing effects on FEP efficiency of HPGe detectors during decay measurements at HIRFL
19
作者 Peng-Song Zheng Fu-Rong Shi +14 位作者 Sunil Dutt Ya-Ling Zhang Yan-Shi Zhang Wei Wang Guang-Shun Li Si-Cheng Wang Hao-Ran Yang Jin-Qi He Peng-Cong Ma Jilehu Gada Xin Ma Fan-Fei Zeng Hao Huang Chen-Sheng Gao Jian-Guo Wang 《Nuclear Science and Techniques》 2025年第5期70-78,共9页
The measurement of low-level radioactivity using high-purity germanium(HPGe)detectors is important in applications such as environmental background radiation,material screening,and rare decays.The dead layers,dead zon... The measurement of low-level radioactivity using high-purity germanium(HPGe)detectors is important in applications such as environmental background radiation,material screening,and rare decays.The dead layers,dead zones,aluminum shell thickness,and diameter of Ge crystals are the most influential factors affecting the performance of HPGe detectors;hence,precise modeling of the physical conditions of the detectors is highly desirable.In this study,the GEANT4 simulation framework with an optimized detector geometry adequately replicated the experimentally recorded spectrum.These detector simulations explored the idea of realizing a dead zone(an inactive volume)at the backend of an n-type coaxial Gecrystal.Using multigamma sources,the effect of true coincidence summing(TCS)on the full energy peak(FEP)efficiency calibration of an HPGe detector was investigated as a function of sample-to-detector distance.Good agreements between the simulated and experimental efficiencies as well as the simulated and analytically calculated summing coincidence correction coefficients were achieved.At a short distance between the source and detector,calculating the correction factors for a strong source posed challenges owing to significant deadtime and pile-up effects of the detection system.The described methodology can efficiently determine summing peak probabilities at short sample-to-detector distances. 展开更多
关键词 Coaxial HPGe detector detector characterization GEANT4 simulation Sum-peak Analytical approach Transfer reaction cross-section
在线阅读 下载PDF
Detector array with digital data acquisition system for charged-particle decay studies
20
作者 Hao Jian Xin-Xing Xu +40 位作者 Kai-Long Wang Jia-Jian Liu Chao-Yi Fu Peng-Jie Li Yan-Yun Yang Guang-Xin Zhang Kang Wang Fang-Fang Duan Long-Hui Ru Guang-Shun Li Bing Ding Yun-Hua Qiang Cen-Xi Yuan Jun-Bing Ma Shi-Wei Xu Yu-Feng Gao Rui Fan Fan-Chao Dai Si-Xian Zha Hao-Fan Zhu Jin-Hai Li Shu-Lian Qin Zhi-Fang Chang Cheng Kong He-Xuan Yan Hao-Wei Xu Jia-Long Ning Bo-Ren Liu Jie Zhou Yu-Dong Chen Bo-Shuai Cai Yu-Ting Wang Hong-Yi Wu Zhi-Xuan Wang Dong-Sheng Hou Hu-Shan Xu Xiao-Hong Zhou Yu-Hu Zhang Meng Wang Zheng-Guo Hu Jenny Lee 《Nuclear Science and Techniques》 2025年第4期140-150,共11页
A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nu... A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nuclei.The digital data acquisition system enables precise synchronization and processing of complex signals from various detectors,such as plastic scintillators,silicon detectors,and germaniumγdetectors.The system's performance was evaluated using theβdecay of^(32)Ar and its neighboring nuclei,produced via projectile fragmentation at the first Radioactive Ion Beam Line in Lanzhou(RIBLL1).Key measurements,including the half-life,charged-particle spectrum,andγ-ray spectrum,were obtained and compared with previous results for validation.Using the implantation–decay method,the isotopes of interest were implanted into two doublesided silicon strip detectors,where their subsequent decays were measured and correlated with preceding implantations using both position and time information.This detection system has potential for further applications,including the study ofβ-delayed charged-particle decay and direct proton emissions from even more exotic proton-rich nuclei. 展开更多
关键词 β-delayed proton decay Double-sided silicon strip detector High-purity germanium detector Digital data acquisition system Implantation–decay correlation
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部