期刊文献+

Phase-sensitive fat suppression steady-state free procession sequence with phase correction 被引量:1

Phase-sensitive fat suppression steady-state free procession sequence with phase correction
原文传递
导出
摘要 Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short scan time, phase errors, especially spatially-dependent phase shift, caused by a variety of factors may result in misplacement of fat and water voxels. In this paper, a novel phase correction algorithm was used to calibrate those phase errors during image reconstruction. This algorithm corrects phase by region growing, employing both the magnitude and the phase information of image pixels. Phantom and in vivo imagings were performed to validate the technique. As a result, excellent fat-suppressed images were acquired by using single-acquisition phase-sensitive SSFP with phase correction. Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short scan time, phase errors, especially spatially-dependent phase shift, caused by a variety of factors may result in misplacement of fat and water voxels. In this paper, a novel phase correction algorithm was used to calibrate those phase errors during image reconstruction. This algorithm corrects phase by region growing, employing both the magnitude and the phase information of image pixels. Phantom and in vivo imagings were performed to validate the technique. As a result, excellent fat-suppressed images were acquired by using single-acquisition phase-sensitive SSFP with phase correction.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第1期328-334,共7页 中国物理B(英文版)
基金 Project partially supported by the National Natural Science Foundation of China (Grant Nos 10527003 and 60672104) the State Key Development Program for Basic Research of China (Grant No 2006CB705700-05) Joint Research Foundation of Beijing Education Committee (Grant No SYS100010401) Beijing Natural Science Foundation (Grant No 3073019)
关键词 steady-state free precession fat suppression phase-sensitive phase correction steady-state free precession, fat suppression, phase-sensitive, phase correction
  • 相关文献

参考文献10

  • 1Hargreaves,BA,Vasanawala,SS,Nayak,KS.Fat-suppressed steady-state free precession imaging using phase detection[].Magnetic Resonance in Medicine.2003
  • 2Carr JC,Simonetti O,Bundy J,et al.Cine MR angiography of the heart with segmented true fast imaging with steady-state precession[].Radiology.2001
  • 3Carr H Y. Physical Review . 1985
  • 4A Oppelt,R Graumann,H Barfuss,H Fischer,W Hartl,W Schajor.FISP: eine neue schnelle Pulssequenz für die Kernspintomographie[].Electromedica.1986
  • 5Lee V S,Resnick D,Bundy J M,Simonetti O P,Lee P,Weinreb J C. Radiol . 2002
  • 6Jung. Magnetic Resonance in Medicine . 2002
  • 7Pereles F S,McCarthy R M,Baskaran V,Carr J C,Kapoor V,Krupinski E A,Finn J P. Radiol . 2002
  • 8Hardy C J,Dixon W T. Proe.ISMRM . 2002
  • 9Scheffler K,heid O,hennig J.Magnetization preparation during the steady state: fatsaturaed 3D TrueFISP[].Magnetic Resonance in Medicine.2001
  • 10EM Haacke,PA Wielopolski,JA Tkach,MT Modic.Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid[].Radiology.1990

同被引文献9