期刊文献+

CMOS direct conversion X-ray detector coupled with fluorinated liquid 被引量:1

在线阅读 下载PDF
导出
摘要 X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors.
出处 《Nuclear Science and Techniques》 2025年第1期59-68,共10页 核技术(英文)
基金 supported by the National Natural Science Foundation of China(No.12235006) the National Key Research and Development Program of China(No.2020YFE0202002.
  • 相关文献

参考文献3

  • 1Hui Wang,Dong Wang,Ran Chen,Yan-Wei Kui,Hong-Bang Liu,Zong-Wang Fan,Huan-Bo Feng,Jin Li,Jun Liu,Qian Liu,Shi Chen,Yuan-Kang Yang,Zhuo Zhou,Zi-Li Li,Shi-Qiang Zhou,Ni Fang.Electronics system for the cosmic X-ray polarization detector[J].Nuclear Science and Techniques,2023,34(5):1-12. 被引量:4
  • 2Rui He,Xiao‑Yang Niu,Yi Wang,Hong‑Wei Liang,Hong‑Bang Liu,Ye Tian,Hong‑Lin Zhang,Chao‑Jie Zou,Zhi‑Yi Liu,Yun‑Long Zhang,Hai‑Bo Yang,Ju Huang,Hong‑Kai Wang,Wei‑Jia Han,Bei Cao,Gang Chen,Cong Dai,Li‑Min Duan,Rui‑Rui Fan,Fang‑Fa Fu,Jian‑Hua Guo,Dong Han,Wei Jiang,Xian‑Qin Li,Xin Li,Zhuo‑Dai Li,Yu‑Tie Liang,Shun Liao,De‑Xu Lin,Cheng‑Ming Liu,Guo‑Rui Liu,Jun‑Tao Liu,Ze Long,Meng‑Chen Niu,Hao Qiu,Hu Ran,Xiang‑Ming Sun,Bo‑Tan Wang,Jia Wang,Jin‑Xiang Wang,Qi‑Lin Wang,Yong‑Sheng Wang,Xiao‑Chuan Xia,Hao‑Qing Xie,He‑Run Yang,Hong Yin,Hong Yuan,Chun‑Hui Zhang,Rui‑Guang Zhao,Ran Zheng,Cheng‑Xin Zhao.Advances in nuclear detection and readout techniques[J].Nuclear Science and Techniques,2023,34(12):281-358. 被引量:29
  • 3李铁成,陶小平,冯华君,徐之海.基于倾斜刃边法的调制传递函数计算及图像复原[J].光学学报,2010,30(10):2891-2897. 被引量:63

二级参考文献62

  • 1Jeffrey T.Olson,Richard L.Espinola,Eddie L.Jacobs.Comparison of tilted slit and tilted edge superresolution modulation transfer function techniques[J].Opt.Engng.,2007,46(1):016403.
  • 2Stephen E.Reichenbach,Stephen K.Park,Ramkumar Narayanswamy.Characterizing digital image acquisition devices[J].Opt.Engng.,1991,30(2):170-177.
  • 3International Organization for Standardization.ISO 12233:2000,Photography--Electronic Still-Picture Cameras--Resolution Measurements[S].
  • 4Ehsan Samei,Nicole T.Ranger,James T.Dobbins et al..Intercomparison of methods for image quality characterization.I.modulation transfer function[J].Med.Phys.,2006,33(5):1454-1465.
  • 5Ann-Katherine Carton,Dirk Vandenbroucke,Luc Struye et al..Validation of MTF measurement for digital mammography quality control[J].Med.Phys.,2005,32(6):1684-1695.
  • 6Andrew D.A.Maidment,Michael Albert.Conditioning data for calculation of the modulation transfer function[J].Med.Phys.,2003,30(2):248-253.
  • 7P.B.Greer,T.van Doorn.Evaluation of an algorithm for the assessment of the MTF using an edge method[J].Med.Phys.,2000,27(9):2048-2059.
  • 8T.Villafana.Effect of microdensitometer scan slit misalignment in MTF determinations[J].Med.Phys.,1975,2(5):255-258.
  • 9I.A.Cunningham,A.Fenster.A method for modulation transfer function determination from edge profiles with correction for finite element differentiation[J].Med.Phys.,1987,14(4):533-537.
  • 10H.Hwang,Y.W.Choi,S.Kwak et al..MTF assessment of high resolution satellite images using ISO 12233 slanted-edge method[C].SPIE,2008,7109:710905.

共引文献93

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部