期刊文献+

寰枢椎改良MAGERL固定术式的生物力学评价 被引量:6

Biomechanical evaluation of several modified Magerl techniques of atlantoaxial fixation
暂未订购
导出
摘要 目的:为寰枢椎后路改良Magerl术式选择提供力学依据。方法:6具新鲜颈椎标本,对寰枢椎行Magerl术及改良Magerl术固定,测量其三维运动范围。结果:Magerl螺钉复合Brooks钢丝固定的稳定性最好,改良Magerl术仍具有相当好的稳定性。结论:Magerl螺钉复合Brooks钢丝固定是保证寰枢段稳定性的最佳术式,当不适合施行标准Magerl术式时,改良Magerl术可作为维持寰枢段稳定性的替代术式。 Objective: To provide biomechanical data for several modif ied Magerl techniques of atlanto-axial fixation. Methods: Six atlantoaxial com plex fresh specimens were used to measure biomechanical data(range of motion, RO M)of Magerl techniques and several modified Magerl techniques. Results: Magerl screw fixation combined with Brooks wiring had the best stability. The modified Magerl techniques also had a better stability. Conclusions: Magerl screw combine d with Brooks wiring fixation technique is the first choice for atlantoxial ins tability. If it is not suitable for Magerl technique, modified Magerl techniqu es are the alternative techniques.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2004年第3期310-312,共3页 Chinese Journal of Clinical Anatomy
基金 广东省自然科学基金团队资助项目(20023001)
关键词 寰枢关节 内固定 生物力学 atlantoaxial joint internal fixation biomechanics
  • 相关文献

参考文献9

  • 1马向阳,刘景发,钟世镇.后路经寰枢椎侧块关节螺钉固定的研究进展[J].中国矫形外科杂志,2003,11(2):131-133. 被引量:19
  • 2杨双石,朱青安,刘景发,欧阳钧,卢智勇,翟文亮,卢海俊,李忠华,钟世镇.枕颈部三维运动范围的测量[J].中国临床解剖学杂志,1998,16(4):360-362. 被引量:7
  • 3Grob D, Crisco JJ Ⅲ, Panjabi MM, et al. Biomechanical evaluation of four different posterior atlantoaxial fixation techniques [J].Spine,1992, 17 (6): 480~490.
  • 4Henriques T, Cunningham BW, Olerud C, et al. Biomechanical comparison of five different atlantoaxial posterior fixation techniques[J].Spine, 2000, 25(22): 2877~2883.
  • 5Haid RW Jr. C1-C2 transarticular screw fixation: technical aspects[J].Neurosurgery, 2001,49(1):71~74.
  • 6Grob D, Jeanneret B, Aebi M, et al. Atlanto-axial fusion with transarticul ar screw fixation[J]. J Bone Joint Surg [Br], 1991,73(6):972~976.
  • 7Madawi AA, Solanki G, Casey AT, et al. Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation[J].J Bone Joint Surg [Br], 1997,79(5): 820~823.
  • 8Mandel IM, Kambach BJ, Petersilge CA, et al. Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws[J]. Spine, 2000, 25(12): 1542~1547.
  • 9Paramore CG, Dickman CA, Sonntag VKH. The anatomical suitability of the C1-2 complex for transarticular screw fixation [J]. J Neuro.surg, 1996, 85 (2):221~224.

二级参考文献10

共引文献24

同被引文献79

引证文献6

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部