摘要 以国家标准分析方法和美国环保局分析方法为基础,采用固相萃取-气相色谱法测定水中多环芳烃。探讨了各条件对测定的影响,确定选用HP 5毛细管柱,手动进样,程序升温。方法的检出限在4~10ng/L,适用于优先监控的16种多环芳烃的同时分析。对煤矿矿坑排水以及污灌区的地下水样中的16种多环芳烃进行测定,并与高效液相色谱法的测定值进行对比,结果基本符合国家标准(相对误差<30.0%)的要求。 Based on the National Standard Methods of China and EPA analysis methods, a new method for the determination of 16 priority pollutants of polycyclic aromatic hydrocarbons (PAHs) by solid phase extraction-gas chromatography has been established. The operating parameters of solid phase extraction and GC analysis parameters are optimized. The effects of various conditions on the determination are studied. HP-5 capillary column is used. Manual sample injection and program-controlled temperature increasing procedure are adopted. The detection limits for PAHs are 4~10 ng/L. The method has been applied to determinate 16 PAHs in water samples. The results are in agreement with those determined by HPLC and accord with National Standards.
出处 《岩矿测试》 CAS CSCD 北大核心 2004年第2期148-152,共5页 Rock and Mineral Analysis
基金 国家自然科学基金(40072080) 国家重大基础研究前期研究专项(2001CCA02400)
关键词 固相萃取 气相色谱法 多环芳烃 毛细管柱 capillary column solid phase extraction gas chromatography(GC) polycyclic aromatic hydrocarbons (PAHs)