摘要
国内5省市对3种新型国产宫内节育器(IUD)包括 TCu200c、宫形器及磁硅器与TCu220c进行随机临床多中心比较性研究。自1987年8月~1988年2月共接受合格对象4 003例。2年随访率99.9%。TCu220c、宫形器和磁硅器2年累积净妊娠率分别为1.6%、2.0%、6.2%和5.2%。两种 TCuIUD 妊娠率较宫形器、磁硅器显著低(P<0.001)脱落率分别为1.5%、1.6%、0.9%和1.9%均低于2%,与 IUD 有关的出血、疼痛、出血和疼痛取出率,分别为1.3%、1.1%、2.3%和2.9%,两种 TCu IUD显著低于宫形器和磁硅器(P<0.05和0.01)。2年修正后续用率分别为95.6%、95.3%和90.6%。以两种 TCu IUD 最高,与后两者相比有显著差异(P<0.001)。
A muhicenter comparative study of the perfor-
mance of TCu 200c,uterine-like and magne-
tic silicone rubber intrauterine devices(IUD) with
TCu 220c as the control device in a cohort of 4 003
subjects was carried out in 5 provincial and municipal
family planning research centers in China.The 2
years follow-up rate of the study was 99.9% and the
net cumulative continuation rates per 100 women re-
lated to IUD use were 95.6%,95.3%,90.6% and
90.0% respectively,which illustrated the higher con-
tinuation rate of both TCu IUDs.However,the preg-
nancy rate of TCu IUDs were 1.6%(TCu 220c) and
2.0%(TCu 200c) while the uterine-like and magne-
tic silicone rubber IUDs were 6.2% and 5.2% respec-
tively.Expulsion rate of 4 types IUD were 1.5%,
1.6%,0.9% and 1.9% respectively.There was no
significant differences.The removal rates for bleed-
ing,pain or both related to the 4 types of IUD were
1.3%,1.1%,2.3% and 2.9% respectively.The re-
moval rate of both the TCu IUDs were significantly
lower than the other 2 devices.
出处
《生殖医学杂志》
CAS
1992年第2期70-73,共4页
Journal of Reproductive Medicine