期刊文献+

Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects 被引量:8

Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
原文传递
导出
摘要 Background Both real-time three-dimensional echocardi ography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects. Methods Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n=6) or distal branch of the left circumflex artery (LCX, n=7) under general anaesthesia. Three to four ml of a perfluoropropane (C 3F 8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and righ t coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals’ hearts were used as control s. Results Left ventricular (LV) mass determined by RT3DE ranged 36.7-68.9 g [mean, (54.6±9.6) g] before coronary artery ligation, and correlated highly (r=0.99) with in vitro measurement of LV mass [range, 38.9-71.1 g; mean, (55.6±9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7-68.9 g; mean, (51.3±12.5) g. Or range, 38.9-71. 1 g; mean, (53.7±12.3) g, respectively] and under-perfused mass [range, 0-21.4 g; mean, (12.0±6.9) g. Or range, 0-19.8 g; mean, (10.8±6.3) g, respectively] after th e LAD ligation (P>0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1-65.4 g; mean, (57.5±5.9 ) g. Or range, 51.5-65.8 g; mean, (57.3±6.4) g, respectively] and under-perfused m ass [range, 0-25.6 g; mean, (13.3±9.6) g. Or range, 0-22.7 g; mean, (12.8±8.1 ) g, respectively] after the LCX ligation (P>0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9-68.6 g [mean, (54.8±10.0) g] a nd there was no significant difference between RT3DE and in vitro measurements of LV mass and under-perfused mass (P>0.05, r=0.99). Further, the under-perfused mass derived from RT3DE [range, 0-25.6 g; mean, (12.7±8.2) g] correlate d strongly with the in vitro measurements [range, 0-22.7 g; mean, (11.9±7.2) g] ( r=0.96). Conclusion RT3DE with MCE is a rapid and accurate method for estimating LV myocardial mass and quantifying perfusion defects. Background Both real-time three-dimensional echocardi ography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects. Methods Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n=6) or distal branch of the left circumflex artery (LCX, n=7) under general anaesthesia. Three to four ml of a perfluoropropane (C 3F 8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and righ t coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals’ hearts were used as control s. Results Left ventricular (LV) mass determined by RT3DE ranged 36.7-68.9 g [mean, (54.6±9.6) g] before coronary artery ligation, and correlated highly (r=0.99) with in vitro measurement of LV mass [range, 38.9-71.1 g; mean, (55.6±9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7-68.9 g; mean, (51.3±12.5) g. Or range, 38.9-71. 1 g; mean, (53.7±12.3) g, respectively] and under-perfused mass [range, 0-21.4 g; mean, (12.0±6.9) g. Or range, 0-19.8 g; mean, (10.8±6.3) g, respectively] after th e LAD ligation (P>0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1-65.4 g; mean, (57.5±5.9 ) g. Or range, 51.5-65.8 g; mean, (57.3±6.4) g, respectively] and under-perfused m ass [range, 0-25.6 g; mean, (13.3±9.6) g. Or range, 0-22.7 g; mean, (12.8±8.1 ) g, respectively] after the LCX ligation (P>0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9-68.6 g [mean, (54.8±10.0) g] a nd there was no significant difference between RT3DE and in vitro measurements of LV mass and under-perfused mass (P>0.05, r=0.99). Further, the under-perfused mass derived from RT3DE [range, 0-25.6 g; mean, (12.7±8.2) g] correlate d strongly with the in vitro measurements [range, 0-22.7 g; mean, (11.9±7.2) g] ( r=0.96). Conclusion RT3DE with MCE is a rapid and accurate method for estimating LV myocardial mass and quantifying perfusion defects.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2004年第3期337-341,共5页 中华医学杂志(英文版)
关键词 real-time three-dimensional echocardiography myocardial contrast echocardiography perfusion defects myocardial infarction real-time three-dimensional echocardiography · myocardial contrast echocardiography · perfusion defects · myocardial infarction
  • 相关文献

参考文献10

  • 1WangXF.Newtrendinnewcenturyandnewyear:prospectofultrasoundinmedicine[].ChinJUltrasonogra.2001
  • 2KissloJ,FirekB,OtaT ,etal.Real timethree dimensionalechocardi ography:thetechnologyandpossibilities[].Echocardiography.2000
  • 3WangXF.Real timethree dimensionalimaging:newbreakthroughinthefieldofultrasonictechnique[].ChinJUltrasonogra.2003
  • 4WangXF.Theprincipleofreal timethree dimensionalechocardiographyanditsforegroundinclinicapplication[].BMEClinMed.2002
  • 5YaoJ,TeupeC,TakeuchiM ,etal.Quantitative3 dimensionalcontrastechocardiographicdeterminationofmyocardialmassatriskandresidualinfarctmassafterreperfusion:experimentalcaninestudieswithintravenouscontrastagentNC100100[].JAmSocEcho.2000
  • 6PorterTR,XieF,KricsfeldA ,etal.Noninvasiveidentificationofacutemyocardialischemiareperfusionwithcontrastultrasoundusingintravenousperfluoropropane exposedsonicateddextroalbumin[].Journal of the American College of Cardiology.1995
  • 7ZhuangL,WangXF,XieMX ,etal.Experimentalstudyofquantitativeassessmentofleftventricularmasswithcontrastreal timethree dimensionalechocardiography[].ChinJMedImagingTechnol.2003
  • 8CamaranoG,JonesM,FreidinRZ ,etal.Quantitativeassessmentofleftventricularperfusiondefectsusingreal timethree dimensionalmyocardialcontrastechocardiography[].JAmSocEcho.2002
  • 9SechtemU.Imagingmyocardialareaatriskandfinalinfarctsize[].EuroHeartJ.2001
  • 10VillanuevaFS.Theuseofmyocardialcontrastechocardi ographyinclinicalevaluationaftermyocardialinfarction[].CoronArteryDis.2000

同被引文献31

引证文献8

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部