期刊文献+

流动注射化学发光法测定环境水样中的铁 被引量:4

Determination of iron in environmental water samples by flow-injection chemiluminescence
在线阅读 下载PDF
导出
摘要 在盐酸介质中,高锰酸钾-甲醛-Fe( )为强化学发光体系,据此,建立了流动注射化学发光法测定铁的新方法,并探讨了发光反应的机理.方法的线性范围为1~100μg.L-1,检出限为0.6μg.L-1,对10μg.L-1的Fe( )标准溶液连续11次测定的相对标准偏差为2.0%.该方法可用于环境水样中微量铁的测定. In hydrochloric acid medium, the chemical system of potassium permanganate-formaldhyde- Fe(Ⅱ) can produce intensive chemiluminescence. Based on it, a new method was proposed for the determination of micro iron by flow injection chemiluminescence. The linear range for the determination was 1~100 μg·L^(-1) and the detection limit was 0.6 μg·L^(-1). The RSD was 2.0% for 11 measurements of 10 μg·L^(-1) Fe(Ⅱ)standard solution. The method has been used for the determination of micro iron in environmental water samples with satisfactory results.
出处 《河南师范大学学报(自然科学版)》 CAS CSCD 2004年第1期65-68,共4页 Journal of Henan Normal University(Natural Science Edition)
关键词 流动注射 化学发光法 高锰酸钾 甲醛 环境水样 flow injection chemiluminescence(Cl) potassium permanganate iron formaldehye
  • 相关文献

参考文献8

  • 1Campos R C, Sointos H R, Grinberg P. Determination of copper, iron, lead and nickel in gasoline by electrothermal atomic absorption spectrometry using three-component solutions[J]. Spectrochimica Acta Part B, 2002, 57: 15.
  • 2Hill A G. Standardized general method for determination of iron with 1,10-phenanthroline [J]. Analyst, 1978, 103: 391.
  • 3Moxtatti J, Krug F J, Pessenda L C R,et a l. Determination of iron in nature-waters and plant-material with 1,10-phenanthroline by flow-injection analysis[J]. Analyst, 1982,107- 659.
  • 4Khuhawar M Y, Lanjwani S N. High-performance liquid chromatographic separation and determination of cobalt( Ⅰ ), cobalt( Ⅲ ) and iron ( Ⅱ ) using bis(salicylaldehyde) tetramethylenediimine[J]. Journal of Chromatography, 1995,695 : 132.
  • 5Yang M S, Thompson M. Thickness-shear mode acoustic-wave sensors and flow-injection analysis [J]. Anal Chim Acta,1992,261: 167.
  • 6Kawashima T, Nakano S. Flow-injection analysis of trace-elements by use of catalytic reactions [J]. Anal Chim Acta,1992, 261: 167-182.
  • 7Kawashima T, Nakano S, Tabata M,et al. Simultaneous flow-injection determination iron( Ⅱ ) and total iron[J]. Anal Chim Acta, 1998,376: 274.
  • 8Evimiridis N P, Thumasoulias N K, Vlessidis A G. Chemiluminescence (Cl) emission generated during oxidation of pyrogallol and its application in analytical chemistry. I. Effect of oxidant compound[J]. Talanta, 1998,46(1): 179.