期刊文献+

流动注射化学发光法测定土壤中的微量铬 被引量:8

Determination of Trace Chromium in Soil with Flowing Injection Chemiluminescence Analysis.
在线阅读 下载PDF
导出
摘要 在聚四氟乙烯压力釜中用混酸恒温溶样,防止了样品的污染和挥发损失.用1-(2-吡啶偶氮)-2-萘酚(PAN)有效地消除了Co^(2+)的干扰,提高了分析的选择性.该法数秒钟即可测定一次试液,适用于批量样品的测定、检出限为6.2×10^(-13)g/ml,多次加标回收率在94.3~105.7%之间,RSD<3%,分析结果令人满意. The paper presents flowing injection chemilumines-cence analysis of trace chromium in soil. The method is rapid, sensitive and accurate after the samples are dissolved with mixed acid in a closed teflon vessel under pressure. Most of common ions do' not interfere with the determination of chromium, and interference from cobalt may be eliminated by addition of PAN masking agent in solution of pH 4. The detection limit of trivalent chromium is 6.2×10-13g/ml.The relative standard deviation is less than 3%(n=3 or 4). The recovery rate is 94.3-105.7%.
出处 《环境科学》 EI CAS CSSCI CSCD 北大核心 1991年第3期54-58,共5页 Environmental Science
基金 河南省教委
关键词 土壤监测 化学发光法 流动注射 trace chromium in soil, determina-tion, flowing injection chemiluminescence analysis.
  • 相关文献

参考文献4

  • 1赵士岑,痕量分析,1988年,4卷,3期,40页
  • 2章竹君,分析测试通报,1983年,2卷,4期,16页
  • 3吕九如,冶金分析,1983年,3卷,3期,131页
  • 4团体著者,土壤和植物中微量元素分析方法,1979年

同被引文献777

引证文献8

二级引证文献83