期刊文献+

两种血清循环免疫复合物测定方法的比较 被引量:3

Comparison of polyethylene glycol precipitation and enzyme-linked immunosorbent assay for the detection of circulating immune complexes
暂未订购
导出
摘要 目的 对测定血清循环免疫复合物 ( circulating immune complexes,CIC)的两种方法 ( PEG沉淀法及 CIC-C1 q ELISA法 )进行评价 ,进一步探讨 CIC测定的临床意义。方法 采用 PEG沉淀法和 CIC-C1 q ELISA法检测肾脏损害、系统性红斑狼疮 ( SLE)、类风湿性关节炎 ( RA)等 86例患者的血清 CIC。结果  86例患者中 PEG沉淀法检测阳性 1 7例 ( 1 9.77% ) ,CIC-C1 q ELISA法检测阳性 3 8例 ( 4 4.1 9% ) ,差异有显著性 ( P<0 .0 5 )。CIC-C1 q ELISA法检测 SLE、RA和肾脏损害患者的 CIC阳性率分别为 1 1 /1 5、5 /8和 2 0 /61 ( 3 2 .79% )。结论 与 PEG沉淀法相比 ,CIC-C1 q ELISA法较敏感 ,适宜于临床推广应用。CIC的阳性与 SLE、RA和肾脏损害有关。 Objective To appraise the two methods[polyethylene glycol(PEG) precipitation assay and CIC-C1q ELISA assay] which were used to detect the circulating immune complexes(CIC) and the clinical significance of CIC. Methods PEG precipitation assay and CIC-C1q ELISA assay were used to detect the levels of CIC in 86 patients with systemic lupus erythematosus (SLE), rheumatoid arthritis (RA) or kidney injury. Results The positive rates of CIC detect- edbyPEGprecipitationassayandCIC-C1qELISAassaywere19.77%and44.19%,thedifferencewassignificant(P< 0.005). The positive rates of CIC detected by CIC-C1q ELISA assay were 11/15, 5/8 and 32.79% respectively in patients with SLE, RA and kidney injury. Conclusions Compared with PEG precipitation assay, CIC-C1q ELISA assay is more sensitive, and can be used in clinical practice for detection of the CIC in different diseases. The positivity of CIC is related to SLE, RA and kidney injury.
出处 《临床输血与检验》 CAS 2004年第2期101-103,共3页 Journal of Clinical Transfusion and Laboratory Medicine
关键词 血清 循环免疫复合物 测定方法 比较 酶联免疫吸附试验 聚乙二醇 PEG沉淀法 Circulating immune complexes Polyethylene glycol ELISA
  • 相关文献

参考文献6

  • 1Mezzano S, Olavarria F, Ardiles L, et al. Incidence of circulating immune complexes in patients with acute poststreptococcal glomeruloneohritis and in patients with streptococcal impetigo[J]. Clin Nephrol, 1986,26(2) : 61-65.
  • 2Szewczyk Z, Falkiewicz K, Kopec W. Detection of circulating immune complexes in patients with glomerulonephritis [J]. Arch Immunol Ther Expl, 1978, 26(6): 577-581.
  • 3Coppo R, De Marchi, Basolo B, et al. Specificity, sensitivity and reproducibility of 2 methods of determining serum immunocomplexes ( solid-phase C1q and polyethylene glu precipitation)[J]. Arch Sci Med ,1982,139(4) : 381-392.
  • 4Aleshkin VA, Nasonov EL, Eremeeva MV, et al. Use of solid-phase Clq-ELISA for detecting circulating immune complexes in human diseases [J]. Ter Arkh,1989,61(6): 113-116.
  • 5Cheung K, Kane D, Robinson MF. Measurement of circulating immune complexes in human sera by enzyme immunoassay[J]. Aust J Exp Biol Med Sci, 1982,60(6) : 593-605.
  • 6Yoshinoya S, Mizoguchi Y, Aotsuka S, et al. Circulating immune complex levels measured by new ELISA kits utilizing monoclonal anti-Clq and anti-C3d antibodies correlate with clinical activities of SLE but not with those of RA[J]. J Clin Lab Immunol, 1992, 38(4): 161-173.