期刊文献+

MeV重离子在固体靶中的平均投影射程计算

CALCULATION OF THE MEAN PROJECT RANGE OF MeV HEAVY IONS IN SOLID TARGETS
原文传递
导出
摘要 根据Biersack角扩散模型,建立了计算MeV重离子在固体靶中的平均投影射程的方法。与新近发表的1.0MeV的In^+,Xe^+,Ta^+和1.0—2.0MeV的Pb^+在Si中的平均投影射程实验数据相比,本文计算值与实验值的最大偏离为8%,而Monte-Carlo(TRIM′86)和PRAL的计算值与实验值的最大偏离分别为23%和22%。这表明本文的计算在预言1.0—2.0MeV的重离子(In^+,Xe^+,Ta^+和 Pb^+)在固体靶(Si)中的平均投影射程是相当成功的。 Based on Biersack's angular diffusion model, an effective method was established for calculating the mean project range of MeV heavy ions in solid targets. The calculated values are compared with recent experimental data on the mean project range for 1.0 MeV In+, Xe+, Ta+ and 1.0-2.0 MeV Pb+ The maximum difference-between present calculated values and experimental data is less than 8%, but the maximum differences between experimental data and calculated values by TRIM 86 and PRAL are 23% and 22%, respectively- The results show that the present calculation procedure is sucsessful for predicting the mean projected range on 1.0-20 MeV such heavy ions as In+, Xe+, Ta+ and Pb+ implanted in solid target (Si).
机构地区 山东大学物理系
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 1992年第11期1820-1824,共5页 Acta Physica Sinica
基金 高等学校博士学科点专项科研基金
  • 相关文献

参考文献1

  • 1Tan Chunyu,Nucl Instr Meth B,1989年,42卷,1页

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部