期刊文献+

运河水用于反渗透进水的试验研究 被引量:2

TEST STUDY ON USING WATER FROM THE GRAND CANAL AS INGOING WATER OF THE REVERSE-OSMOSIS SYSTEM
在线阅读 下载PDF
导出
摘要 对运河水用于反渗透进水的预处理方案进行了研究 ,主要为去除水中有机物和降低水的浊度 ,其中包括 :(1 )确定原水中有机物含量及其分子量的分布范围 ;(2 )对混凝剂及其浓度进行选择 ;(3)确定助凝剂和低浊添加剂的作用 ;(4 )原水pH值对混凝效果的影响 ;(5 )NaClO氧化试验 ;(6 )活性炭吸附有机物试验。根据试验结果 。 The pretreatment scheme of using water from the Grand Canal as ingoing water of the reverse osmosis system has been studied. The main points are elimination of organics in the water, and reduction of the water turbidity, including: (1) determining the content of organics in raw water and the distribution range of its molecular weight; (2) selecting cogulant and its concentration; (3) defining the effects of cogulating aid and low turbidity additives; (4) considering the infuence of pH value in raw water upon the cogulating effectiveness; (5) conducting oxidation test for NaCIO; (6) performing test of organics abosorbing ability for activated carbon. Based on the results of test, an effective and practical pretreatment process has been put forward.
出处 《热力发电》 CAS 北大核心 2003年第12期60-63,77,共5页 Thermal Power Generation
  • 相关文献

参考文献4

  • 1.DL/T 5068-1996.火力发电厂化学设计技术规定[S].中华人民共和国电力工业部,..
  • 2电力工业部西安热工研究所.低温低浊水除浊工艺的研究[Z].,1992..
  • 3能源部西安热工研究所.火电厂锅炉补给水预处理技术的研究[Z].,1991..
  • 4西安热工研究所.火力发电厂水汽试验方法标准规程汇编[Z].,1995..

同被引文献15

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部