期刊文献+

外环流反应器结构与操作参数对气含率的影响

Influences of structure and operational parameters on gas hold-up in an external-loop reactor
原文传递
导出
摘要 在中试气提式外环流冷模反应装置上,研究表观气速UG、液相主体流速UL和气含率εG的关系,揭示小装置上反映不出的现象并为生产提供指导。反应装置高2.5m,由一个上升管与两个下降管组成,其内径分别为0.47m和0.08m,已接近于中试规模。对不同开孔方向和开孔数的气体分布器,分气液及气液固情形进行研究。结果表明:UL随UG升高呈线性上升;εG随UG增大而增大,二者也呈线性变化;εG随UL增大略有增大;分布器开孔向上比向下具有高的εG;活性炭加入500g比加入250g更能提高εG。 This paper studied the relationships of the superficial gas velocity, U_G, the liquid loop velocity, U_L, and the gas hold-up, ε_G, in a pilot-scale airlift-external-loop reactor to investigate larger scale effects that do not exist in small reactors. The pilot-scale airlift-external-loop reactor was 2.5 m in height with one riser and two downcomers. The riser inner diameter was 0.47 m and the downcomer inner diameters were 8 cm. For gas-liquid and gas-liquid-solid conditions, the effects of U_G on U_L and U_G or U_L on ε_G were investigated for different hole orientations and hole numbers in the gas distributors. The results show that U_L and ε_G increase linearly with U_G. The increase of ε_G with U_L is not obvious, but is higher with an upward gas distributor than with a downward gas distributor. ε_G is higher with 500 g active carbon than with 250 g.
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 2003年第12期1620-1622,1630,共4页 Journal of Tsinghua University(Science and Technology)
关键词 结构 操作参数 气含率 化学反应过程 气提式外环流反应器 液相主体流速 表观气速 chemical reaction airlift-external-loop reactor liquid loop velocity gas hold-up apparent gas velocity
  • 相关文献

参考文献6

  • 1Dhaouadi H, Poncin S, Hornut J M, et al. Mass transfer in an external-loop airlift reactor: experiments and modeling [J]. Chem Eng Sci, 1997, 52(21-22): 3909-3917.
  • 2Delnoij E, Kuipers J A M, van Swaaij W P M. Dynamic simulation of gas-liquid two-phase flow: effect of column aspect ratio on the flow structure [J]. Chem Eng Sci, 1997,52(21 - 22): 3759- 3772.
  • 3Douek R S, Livingston A G, Hewitt G F J. Instabilityphenomenon in an external-loop three phases gas-liquid-solidairlift reactor [J]. AIChE, 1995, 41(11): 2508- 2511.
  • 4Merchuk J C, Contreras A, Garcia F, et al. Local hold-upand liquid velocity in air-lift reactors [J]. Chem Eng Sci,1998, 53(4): 709-719.
  • 5杨卫国,王金福,周黎明,金涌.气液固三相循环流化床气液传质行为[J].化工学报,1999,50(5):700-704. 被引量:8
  • 6李天成,辛峰,李鑫钢,王富民,廖晖,王宇新.气提式外环流反应器的液相流动模型[J].化学反应工程与工艺,2001,17(4):349-357. 被引量:1

二级参考文献11

共引文献7

相关作者