摘要
龙泉换流站站系统调试时,分别对极 和极 换流变压器进行了投切试验。通过试验对换流变压器的绝缘、保护等进行了考核,对试验中的数据进行了记录。
In station system test, the converter transformers of PoleⅠand PoleⅡpassed the closing and opening test. Through the test the insulation, protection and etc. of the converter transformers were checked. The data in the test were recorded.
出处
《湖北电力》
2003年第B12期23-26,共4页
Hubei Electric Power
关键词
龙泉换流站
换流变压器
投切试验
开关参数
converter station
converter transformer
closing and opening test