期刊文献+

ID-ICP-MS测定高纯石英中微量铀的方法研究 被引量:5

Determination of Trace Uranium in High Purity Quartz by Means of ID-ICP-MS
在线阅读 下载PDF
导出
摘要 采用一种脉冲增压微色谱柱 ,阴离子交换树脂 ,分离富集高纯石英中的微量铀 ,分离效果好 ,本底低。样品处理用低温密封闷罐酸溶。同位素稀释电感耦合等离子体质谱 (ID ICP MS)测定高纯石英中的微量铀 ,方法检出限低 :0 .1ng/ g (3σ ,n =10 ) ,分析速度快 。 A method called pulse-pressurized capillary column is used for preconcentration and separation of uranium, followed by determination of trace uranium in high purity quartz by ID-ICP-MS. Acid is used to dissolve the sample in an airproof vessel at a low temperature. The result of GSD-10 indicates that good precision and veracity can be achieved, and that the limit of determination is low (0.1 ng/g).Therefore,ID-ICP-MS is a good technique for determining trace element.
出处 《地球学报》 EI CAS CSCD 北大核心 2003年第6期627-630,共4页 Acta Geoscientica Sinica
关键词 同位素稀释 电感耦合等离子体质谱法 微量铀 高纯石英 脉冲增压微色谱柱 isotope dilution (ID) inductively coupled plasma mass spectrometry uranium high purity quartz
  • 相关文献

参考文献1

二级参考文献71

  • 1Grenville Holland. Plasma Source Mass Spec-trometry : New Developments and Applications. Cambridge : Royal Society of Chemistry,1999,299.
  • 2Grenville Holland,Scott D Tanner. Plasma Source Mass Spectrometry: the New Millennium. Cambridge : Royal Society of Chemistry, 2001,427.
  • 3Howard E Taylor. Inductively Coupled Plasma-Mass Spectrometry : Practices and Techniques,San Diego : Academic Press, 2001, 294.
  • 4Akbar Montaser. Inductively Coupled Plasma Mass Spectrometry,New York : J. Wiley, 1998,964.
  • 5Roy W Morrow, Jeffrey S Crain. Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations. West Conshohocken, Pennsylvania : ASTM, c1998, 145.
  • 6Roy W Morrow, Jeffrey S Crain. Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations. West Conshohocken, Pennsylvania: ASTM, c1995, 145.
  • 7Wangzhao Zhu. Advanced Inductively Coupled Plasma Mass Spectrometry Analysis of Rare Earth Elements. Environmental Applications,Rotterdam : Balkema, 1999,157.
  • 8Narong Praphairaksit, R S Houk. Attenuation of Matrix Effects in Inductively Coupled Plasma Mass Spectrometry with a Supplemental Electron Source inside the Skimmer. Analytical Chemistry, 2000, 72(11): 2351~2355.
  • 9Scott D Tanner, Lisa M Cousins, Douglas DJ. Reduction of Space Charge Effects Using a Three-Aperture Gas Dynamic Vacuum Interface for Inductively Coupled Plasma-Mass Spectrometry. Appl. Spec., 1994,48 (11).
  • 10DeNoyer ER, Thomas RJ, Cousins LM. A New Approach to Extending the Dynamic Range in ICP Mass Spectrometry. Spectroscopy, 1997, 12 (2), 56~61.

共引文献129

同被引文献113

引证文献5

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部