期刊文献+

增压排空阴离子交换法分离-ICP-MS测定铀基体中痕量稀土 被引量:5

Separation of Rare Earths From Uranium by Anion Exchange With Pre-exclusion of Loading Solution Under Pressure and Determination by ICP-MS
在线阅读 下载PDF
导出
摘要 采用增压排空的阴离子交换柱实现了铀基体与痕量稀土元素的分离。结果表明,全流程对稀土的回收率在96%~106%之间,整个分离过程可在20min内完成。用ICP MS测量铀基体中痕量稀土的检测限为1×10-12g/mL。用该方法分析U3O8成分分析标准参考物质GBW04207中的痕量稀土含量,测量结果与参考值符合良好。 An intermittently pressurized anion exchange column is used for separation of trace rare earth elements (REES) from uranium before ICP-MS measurements. The whole separation can be completed within 20 min. The recoveries for all REES are in the range of 96%~106%. Comparing with previous methods, this technique consumes less chemicals and produces less waste. The applicability and reliability of this procedure is demonstrated by the good accordance between results determined by this method and the recommended values for REES in a standard reference material (GBW04207). It is proved that this method would be useful for analysis of trace REES impurities in uranium metal and its oxides.
出处 《核化学与放射化学》 CAS CSCD 北大核心 2004年第2期118-121,共4页 Journal of Nuclear and Radiochemistry
关键词 增压排空阴离子交换法 分离 电感耦合等离子体质谱 铀基体 稀土 痕量分析 pressurized & evacuated column anion exchange resins inductively coupled plasma-mass spectrometry(ICP-MS) uranium rare earth elements(REES)
  • 相关文献

参考文献5

二级参考文献78

  • 1龚治湘,宋金如.P_(350)微孔快速色谱柱分离富集铀的性能研究[J].高等学校化学学报,1994,15(8):1128-1131. 被引量:19
  • 2龚治湘 宋金如.减压微色谱柱技术在分析化学中的应用研究[A]..核工业地质分析测试技术与质量管理研讨会论文集[C].北京:核工业地质研究院,2002..
  • 3Grenville Holland. Plasma Source Mass Spec-trometry : New Developments and Applications. Cambridge : Royal Society of Chemistry,1999,299.
  • 4Grenville Holland,Scott D Tanner. Plasma Source Mass Spectrometry: the New Millennium. Cambridge : Royal Society of Chemistry, 2001,427.
  • 5Howard E Taylor. Inductively Coupled Plasma-Mass Spectrometry : Practices and Techniques,San Diego : Academic Press, 2001, 294.
  • 6Akbar Montaser. Inductively Coupled Plasma Mass Spectrometry,New York : J. Wiley, 1998,964.
  • 7Roy W Morrow, Jeffrey S Crain. Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations. West Conshohocken, Pennsylvania : ASTM, c1998, 145.
  • 8Roy W Morrow, Jeffrey S Crain. Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations. West Conshohocken, Pennsylvania: ASTM, c1995, 145.
  • 9Wangzhao Zhu. Advanced Inductively Coupled Plasma Mass Spectrometry Analysis of Rare Earth Elements. Environmental Applications,Rotterdam : Balkema, 1999,157.
  • 10Narong Praphairaksit, R S Houk. Attenuation of Matrix Effects in Inductively Coupled Plasma Mass Spectrometry with a Supplemental Electron Source inside the Skimmer. Analytical Chemistry, 2000, 72(11): 2351~2355.

共引文献138

同被引文献64

引证文献5

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部