期刊文献+

1025t/h锅炉高温过热器超温分析及改造 被引量:4

Analysis and Improvement for the Overheating of High-Temperature Superheater in a 1025t/h Power Station Boiler
在线阅读 下载PDF
导出
摘要 通过应用热偏差理论对国产1025t/h电站锅炉高温过热器超温问题进行分析研究发现;超温的根本原因是沿炉宽烟气侧热负荷分布与蒸汽流量分布不匹配。针对该炉型的特点提出改造方案,不仅降低了高温过热器外圈管出口汽温,同时减少了减温水量,提高了过热蒸汽出口温度。改造后测得的汽温值与计算值吻合得较好。 According to the analysis for the overheating of hightemperature superheater in a 1025t/h utility boiler through the heat deviation theory, the discord between heat load distribution on gas side and flow distribution on stean side across the furnace width is the main reason for causing overheating. A retrofit proposal for the special boiler type has been implemented, and output steam temperature of outer tube loop was dropped, the flow of desuperheater spray was also decreased, the output steam temperature of superheater was rised. The steam temperature value of calculation well agreed with ones of measurement after retrofit.Figs 9 and refs 4.
出处 《动力工程》 CSCD 北大核心 2003年第6期2769-2772,共4页 Power Engineering
关键词 电站锅炉 高温过热器 超温 热偏差 power station boiler high-temperature superheater overheating heat deviation
  • 相关文献

参考文献4

  • 1陈之航 赵再三.单相流体在并联管组集箱中的流量分布和热力偏差的理论及计算[J].锅炉技术,1974,(10).
  • 2王孟浩.大容量电站锅炉过热器再热器温度偏差原因及防止对策[J].锅炉技术,1992(3):1-11. 被引量:27
  • 3Luo Yong-hao, Wu Zhen-yao, Wng Meng-hao. A Discrete Model for the Pressure Distribution in Boiler Manifolds[C]. International Conference on Power Engineering 97,Tokyo, Japan, 1997,7.
  • 4Luo Yong-hao, Wang Meng-hao. Analysis of ovrrheating tube bursts in reheaters of 300-600MW tangentially firedboilers[C]. International Joint Power Generation Conference-99 and International Conference on Power Engineering-99, San Francisco U. S. A. ,1999,7.

共引文献29

同被引文献25

  • 1袁益超,陈之航.大容量电站锅炉过热器及再热器系统研究的现状与发展[J].动力工程,1993,13(6):42-46. 被引量:8
  • 2周振起,李保峰,张炳文.喷水减温对机组热经济性的影响[J].锅炉技术,2006,37(3):15-18. 被引量:17
  • 3唐从耿,刘丛涛,张裕嘉,肖华,胡兴胜,吴安.锅炉受热面热偏差的改进措施[J].动力工程,2006,26(6):773-779. 被引量:17
  • 4XU Li-jun, KHAN J A, CHEN Zhi-hang. Thermal load deviation model for superheater and reheater of a utility boiler[J]. Applied Thermal Engineering, 2000,20 (6) :545-558.
  • 5MOELBAK T. Advanced control of superheater steam temperatures-an evaluation based on practical applications[J]. Control Engineering Practice, 1999,7 (7):1-10.
  • 6OTHMAN H, PURBOLAKSONO J, AHMAD B. Failure investigation on deformed superheater tubes [J]. Engineering Failure Analysis, 2009,16 (1): 329- 339.
  • 7KWON O, MYERS M, KARSTENSEN A D, etal. The effect of the steam temperature fluctuations during steady state operation on the remnant life of the superheater header[J]. International Journal of Pressure Vessels and Piping, 2006,83 (5): 349-358.
  • 8梁松茂.600MW电站锅炉减温水过量的原因分析及对策[D].北京:北京交通大学,2008.
  • 9JERZY T, KRZYSZTOF W. Two-dimensional modeling of deposits formation on platen superheaters[J]. Fuel, 2009, 88(8):1466-1471.
  • 10王洪涛,王信强.过热器超温问题的研究[J].华北电力技术,2007(11):30-31. 被引量:5

引证文献4