期刊文献+

循环流化床锅炉灰渣可燃物测试方法研究 被引量:3

STUDY ON TESTING METHODS OF COMBUSTIBLES IN ASH AND SLAG OF CFB BOILERS
在线阅读 下载PDF
导出
摘要 对加湿的循环流化床锅炉灰渣可燃物的几种测定方法进行了分析比较 ,认为传统的灼烧减量法 (LOI)和直接测量法 (DDM)测量结果偏高 ,采用热重分析法与光谱联用 (TGAFTIR)修正的TGA测量结果最接近实际值 ;草酸酸洗干燥后按RS 2 6 183标准采用LOI测量并修正的方法 ,具有更高的准确度 。 Several methods for determining combustibles in ash and slag from wetting CFB boilers have been analysed and compared, it is considered that the measured results of traditional LOI method and DDM method were somewhat higher, but the measured results of TGA method and corrected by using jointly TGA and FTIR were coming near to practical value. However, the measured value of using TGA method and corrected according to RS-26-1-83 standard after acid-cleaning with oxalic acid and drying-out has much higher accuracy, and its operable ability being comparatively strong.
出处 《热力发电》 CAS 北大核心 2003年第10期14-17,共4页 Thermal Power Generation
基金 国家重点基础研究发展规划项目 (G2 0 0 0 0 2 630 9)
  • 相关文献