摘要
青海桥头铝电公司N1 2 5 - 1 3.2 4 /5 35 /5 35型汽轮机调速汽门从安装到本次改造之前经常出现卡涩现象 ,通过分析和采取一系列改造措施后 ,使调速汽门能够正常、稳定运行。文章分析了N1 2 5 - 1 3.2 4 /5 35 /5 35型汽轮机调速汽门卡涩的原因并提出了处理方法 。
The speed governing steam door of N125-13.24/535/535 turbine often appears seizure phenomenon before this improvement in Qinghai Qiaotou aluminium electricity company,After taking a series of improving measures the speed governing steam door can run normally and steadily.The paper analyses the reason of seizure and puts forward the treatment method, and it possesses certain technological refernce value.
出处
《青海电力》
2003年第3期27-29,共3页
Qinghai Electric Power