摘要 采用熔融法制样,用X射线荧光光谱法对耐火材料中的Na2O、MgO、Al2O3、SiO2、K2O、CaO、TiO2、Cr2O3、MnO、Fe2O3、ZrO2、HfO2组分进行测定,使用康普顿散射线作内标和经验系数法校正基体效应,经标准物质检验与标准值吻合,大部分组分的RSD<5%(n=10)。 A method for the determination of Na2O, MgO, Al2O3, SiO2, K2O, CaO, TiO2, Cr2O3,MnO, Fe2O3, ZrO2 and HfO2 in the refractory materials by Xray spectrometry with fusion sample preparation technique was developed. The calibration was carried out with certified reference materials. The absorption enhancement effects between elements were corrected by experience coefficient method with scattered radiation as internal standard. The method has been applied to the determination of Na, Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe, Zr and Hf in standard reference materials. The results are in agreement with certified values with precision of <5% RSD (n=10). 
出处 《岩矿测试》 CAS CSCD 北大核心 2003年第3期217-220,224,共5页 Rock and Mineral Analysis
关键词 X射线荧光光谱法 耐火材料 经验系数 散射线内标 refractory material X-ray fluorescence spectrometry experience coefficient, scattered radiation as internal standard
  • 相关文献

参考文献8

二级参考文献22

  • 1李国会,卜维,樊守忠.X射线荧光光谱法测定硅酸盐中硫等20个主、次、痕量元素[J].光谱学与光谱分析,1994,14(1):105-110. 被引量:97
  • 2李国会,光谱学与光谱分析,1988年,9卷,1期,66页
  • 3王毅民,岩矿测试,1988年,7卷,1期,76页
  • 4李国会,物探与化探,1986年,10卷,1期,60页
  • 5徐积荣,岩矿测试,1986年,5卷,3期,201页
  • 6刁桂年,分析化学,1983年,11卷,1期,45页
  • 7吉昂,光谱学与光谱分析,1983年,3卷,1期,38页
  • 8马光祖,理化检验,1983年,19卷,4期,18页
  • 9Raschka H,分析化学,1982年,11卷,10期,609页
  • 10王毅民,Mar Min,1991年,10卷,3期,259页

共引文献196

同被引文献253

引证文献12

二级引证文献57

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部