期刊文献+

蒸发冷却大电机定子主绝缘的试验研究 被引量:5

Experiment Study on the Main Insulation of Stator of Evaporative Cooling Large Generator
在线阅读 下载PDF
导出
摘要 针对大型蒸发冷却电机的定子设计出一种新的绝缘结构 ,由冷却介质承担主绝缘使主绝缘厚度大幅减薄。用13.8k V电压等级的定子模拟线棒试验的结果表明 ,这种新型主绝缘可行。 Based on the insulation requirements of stator of high voltage generator and special characteristics of evaporation coolant, a kind of new stator insulation structure is designed. The thickness of main insulation is enormously decreased and the main insulation intensity relays on the coolant. Choosing 13 8 kV evaporative turbo generator as an example, whether the new structure is reasonable and feasible is verified by some high voltage experiments. The results show that this new type of insulation is suitable.
作者 栾茹
出处 《高电压技术》 EI CAS CSCD 北大核心 2003年第9期8-9,共2页 High Voltage Engineering
关键词 蒸发冷却 大电机 定子 主绝缘 试验 evaporative cooling insulation structure stator
  • 相关文献

参考文献5

  • 1丁瞬年.大型电机的发热与冷却[M].北京:科学出版社,1992.1-28.
  • 2栾茹,顾国彪.蒸发冷却汽轮发电机定子绝缘结构的模拟试验及分析[J].大电机技术,2002(6):23-26. 被引量:11
  • 3顾国彪.蒸发冷却应用于50 MW汽轮发电机的研究和开发[R].北京:中科院电工研究所,1992..
  • 4顾国彪.蒸发冷却应用于50 MW汽轮发电机的研究和开发[R].北京:中科院电工研究所,1992..
  • 5丁瞬年.大型电机的发热与冷却[M].北京:科学出版社,1992..

二级参考文献2

  • 1顾国彪.蒸发冷却应用于50MW汽轮发电机的研究和开发[C].中国科学院电工研究所论文报告集,23,1997,7,5-15.
  • 2李作之,等.11千伏级蒸发冷却电机定子绝缘[C].中国科学院电工所论文报告集第5集,1982,4:31-35.