由于国民经济的快速发展 ,电力系统的负荷越来越大 ,线路非全相时的零序电流有了很大增加 ,本文通过对线路非全相时零序电流的计算分析 ,提出了线路非全相时保护整定及运行中应注意的问题及解决的方法。
With the national economy rapidly developing, load is continuously increasing on electric power lines and the zero sequence current is greatly increased on power line operating with phase failure.The paper calculates and analyzes the zero sequence current in power line during phase failure,meanwhile,it presents the problem to notice and the way to solve it when protection is set and operated under such cases.
出处
《继电器》
CSCD
北大核心
2003年第7期81-83,共3页
Relay