本文针对空调分体室内机采用的贯流风机的特点,对分体室内机采用四折式蒸发器时的贯流风机系统,采用FLUENT(CFD)软件,进行了2D内流模拟分析,指出了内流中易出现回流的三个位置。结果表明,采用多折式蒸发器结构具有较好的内流特性,具有良好的性能和声质量,并得到试验结果的验证,在产品中得到了应用。
The paper aim at Air-condition Cross-Flow Fan that adopt the machine's characteristics, right cent the indoors the machine adoption four fold Cross-Flow breeze machine for type to evaporate system, adoption FLUENT(CFD) software, proceeds 2D in-flow numerical simulation. In the conditioner at three position existed obvious reverse flow from inlet to outlet. Through analyze the result the enunciation, the air-condition Cross-Flow have the good inter-flow characteristic, and have the quantity of good function harmony, and combine the verification of getting to experiment the result, and got the application in the product.