期刊文献+

基于比例法的高准确度测温电路及非线性校正 被引量:5

Temperature measurement circuit with high accuracy and non-linearity compensa tion based on the scaling method
在线阅读 下载PDF
导出
摘要 介绍了一种高准确度铂电阻测温电路,采用四线制接法,克服了长引线电阻所带来的误差。测量方法采用比例法,不仅对电源要求低,还不必考虑零点、温度漂移等问题,测量准确度只与铂电阻的准确度有关。同时,采用牛顿迭代法进行非线性校正,并通过数值滤波处理,在0~140℃温度范围内的测量误差为±0.1℃。 A kind of temperature measurement circuit for plati nu m resistor with high accuracy based on the scaling method is introduced.Fourwi re conjunction method is adopted and thus the error caused by longwire resista nce is reduced.There is no need to adopt high precision power supply and none to consider the problems such as zero shifts,temperature shifts,etc.Thus high accu racy within ±0.1?℃ is able to be maintained in the region of 0~140?℃ b y scaling and numerical filtering.
出处 《传感器技术》 CSCD 北大核心 2003年第6期17-18,23,共3页 Journal of Transducer Technology
基金 联合国和湖北省产品质量监督检验所共同资助(2002AA101C61)
关键词 铂电阻 比例法 非线性校正 数值滤波 温度测量 四线制接法 platinum resistor scaling method non-linearity compensation numerical filtering temperature measurement