摘要  用国内近年新研制的CeF3闪烁体和常用闪烁体ST401分别配特性相同的光电倍增管,构成两种闪烁体探测器,在强度不随时间变化的DD中子源场中测量了这两种闪烁探测器的相对灵敏度,测量结果表明:CeF3闪烁探测器对DD中子的灵敏度比同尺寸ST401的灵敏度低一个量级以上。 Two kinds scintillation detectors are composed of cerium fluoride (CeF3) and ST401 with photomultiplier tube respectively, the experimental sample of CeF3 is the newly developed inorganic scintillator in China in recent years, ST401 is a common plastic organic scintillator. The DD neutron relative sensitivity of the two scintillation detectors are measured in DD neutrons source radiation field, which indicate that the DD neutron sensitivity of CeF3 scintillation detector is less than onetenth that of ST401 with same volume.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2003年第7期721-724,共4页 High Power Laser and Particle Beams
基金 中国工程物理研究院基金资助课题(J09 305)
关键词 CeF3 三氟化铈 闪烁探测器 DD中子 相对灵敏度 无机闪烁体 辐射探测 Cerium fluoride(CeF_3) Inorganic scintillator Radiation detection DD neutron source Neutron sensitivity
  • 相关文献

参考文献13

二级参考文献14

  • 1华欣生.测量强脉冲混合辐射场的探测器件[J].核电子学与探测技术,1985,5.
  • 2Liu R,Nucl Sci Tech,1998年,2期,82页
  • 3中科院原子能所快中子激发曲线组,加速器单能中子源常用数据手册,1976年
  • 4刘荣,核电子学与探测技术,1999年,19卷,6期,428页
  • 5丁厚本,中子源物理,1984年,203页
  • 6Anderson D F. IEEE Transaction on Nuclear Science, 1989, 36:137
  • 7Moses W W, Dernenzo S E. IEEE Transaction on Nuclear Science, 1989, 36:173
  • 8Alibikov A. Pulse Ionization Radiation Detector. Beijing: Atomic Energy Press, 1983. 7(in Chinese)(A.阿利比科夫. 脉冲电离辐射探测器. 北京:原子能出版社,1983.7)
  • 9汪兆民,许咨宗,宫竹芳,陈宏芳,许长补,B.Dezillie.强辐照场下氟化铈(CeF_3)的荧光特性[J].原子与分子物理学报,1998,15(2):229-234. 被引量:9
  • 10伍健,许彤,李澄,汪晓莲,汪兆民,李宏杰,陈宏芳,许咨宗.一种精确确定闪烁晶体光产额的方法[J].高能物理与核物理,1998,22(6):481-485. 被引量:5