基于分布参数线路模型的精确故障测距算法 被引量:21

An accurate fault location algorithm based on distributed parameter line model
在线阅读 下载PDF
导出
摘要 为消除负荷电流和线路模型不准确给双端量故障测距带来的影响,提出一种基于分布参数线路模型的精确测距算法。算法以均匀传输线的波动方程(长线方程)为基础,利用线路两端电压、电流的正序故障分量以及线路正序参数直接计算故障距离。算法无需故障类型判别,不受系统阻抗、故障电阻、负荷电流以及分布电容的影响。基于EMTP的数字仿真结果验证了该算法的正确性和高精度。 To remove the effect on two-terminal fault location by load current and imperfect line model, an accurate fault location algorithm based on distributed parameter line model is proposed in this paper. Basing on the wave equation of homogeneous transmission line, the fault location is directly calculated by using positive sequence fault components of voltages and currents derived at both line ends, as well as line positive sequence parameters. The algorithm does not need fault type identification, and its accuracy is not affected by fault resistance, system impedance , pre-fault load current and shunt capacitance. The EMTP based digital simulation has shown its correctness and high accuracy.
出处 《继电器》 CSCD 北大核心 2003年第6期42-45,共4页 Relay
关键词 输电线路 分布参数线路模型 精确故障测距算法 数字仿真 电力系统 fault location transmission lines distributed parameter fault component
  • 相关文献

参考文献3

  • 1卢继平,叶一麟.适用于任何具体结构的输电线路精确故障定位[J].电力系统自动化,1998,22(11):40-43. 被引量:11
  • 2Johns A T, Jamali S, Accurate Fault Location Technique for Power Transmission Lines [ J]. IEEE Proc, Vol. 137, Pt. C,No.6, Nov. 1990.
  • 3Girgis A A, Hart D G, et al. A New Fault Location Technique for Two and Three-Terminal Lines[J]. IEEE Trans on PWRD,Vol.7,No. 1 Jan. 1992.

二级参考文献5

  • 1梁军,电力系统自动化,1997年,21卷,9期
  • 2Lei Ming,DPSP & C’94,1994年
  • 3卢继平,International Conference on Power System Technology,1991年
  • 4吴维韩,电力系统过电压数值计算,1989年
  • 5贺家李,超高压输电线故障分析与继电保护,1987年