期刊文献+

双转子柱体超声波电机运行机理与实验研究 被引量:18

OPERATION MECHANICS AND EXPERIMENTAL RESRARCH OF CYLINDRICAL ULTRASONIC MOTOR WITH DOUBLE ROTORS
在线阅读 下载PDF
导出
摘要 环形行波型超声波电机小直径条件下,输出性能逐渐失去低速大扭矩的特点。而柱体弯曲振动超声波电机是靠圆柱定子端部的摇头振动并通过摩擦来驱动转子的,定子的直径越小,摇头振动的幅值越大,因而,小直径时更能显示出这种电机的优越性。该文阐述了双转子柱体弯曲振动超声波电机的运行机理,证明了定子表面质点运动轨迹为一椭球;利用ANSYS有限元软件分析了电机的弯曲振动模态;用阻抗特性分析仪分析了电机的阻抗特性和相位特性;制作了直径为20mm、有两个转子的柱体弯曲振动超声波电机, 并对其输出特性进行了测试,最大转矩达0.16Nm、最高转速为220r/min。 Traveling wave ring-type ultrasonic motor will lose the characteristic of large torque with low speed when it's diameter is small. Otherwise the cylindrical ultrasonic motor uses bending vibration of the top surface of stator to drive rotor. The smaller the diameter of stator is, the bigger the amplitude of vibration will be. The operation mechanics of cylindrical bending vibration ultrasonic motor with double rotors is represented in this paper. It is approved that the motion locus of top point of stator is an elliptical sphere. The motor's bending vibration mode is analyzed by ANSYS. The motor's character of impedance and phase contrast has been surveyed by using impedance characteristic analysis instrument. The cylindrical bending vibration ultrasonic motor with two rotors and 20mm in diameter is fabricated, and it's output performance is tested. The largest output torque is 0.16Nm, the highest output speed is 220 r/min.
出处 《中国电机工程学报》 EI CSCD 北大核心 2003年第1期84-87,共4页 Proceedings of the CSEE
基金 国家自然科学基金项目(50277006) 教育部优秀青年教师计划项目(教育部教人司2000-40) 江苏省教育厅高新技术产业化基金项目(JH01-007) 江苏省教育自然科学基金项目(02KJD470005)。~
关键词 环形行波型超声波电机 运行机理 实验研究 有限元方法 定子 双转子柱体超声波电机 ultrasonic motor cylindrical stator double rotor operation mechanics bending vibration
  • 相关文献

参考文献7

  • 1[1]Ueha S,Tomikawa Y.Ultrasonic motors theory and applications [M].Oxford Science Publications,1993.
  • 2胡敏强,石斌,钱俞寿.超声波电动机控制技术研究的发展及现状[J].微电机,1998,31(2):30-33. 被引量:10
  • 3[3]Minoru Kurosawa,et al.An ultrasonic motor using bending vibrations of a shot cylinder[J].IEEE Transactions on Ultrasonis Ferroelectrics and Frequency Control,1989,36(5):517-521.
  • 4[4]Morita T,Kurosawa M,Higuchi T.An ultrasonic motor using a bending cylindrical transducer based on PZT thin film, Sensors and Actuators[J].1995,A50(1):75-80.
  • 5[5]Morita T,Kurosawa M,Higuchi T.A cylinder micro-ultrasonic motor [J].Ultrasonics,2000,38 (1):33-36.
  • 6[6]Lu Pin,Lee KwOK Hong,et al.A kinematic analysis of cylindrical ultrasonic micromotors[J].Sensors and Actuators,2001,A87(8):194-197.
  • 7[8]Dong Shuxiang,Wang Shuxin,Shen Wenjiang,et al.A miniature piezoelectric ultrasonic motor based on circular bending vibration mode[J].IEEE/ASME Transactions On Mechatronics,2000,5(4):325-330.

二级参考文献2

  • 1指田年生(日.新生工业).振动片型和表面波型超声波电机[J].应用机械工学(日),1983,24(5).
  • 2Takeshi Hatsuzawa.Speed Control Charateristics and Digital Servosystem of a Circular Traveling Wave Motor.Rev.Sci,Instrum.1986,57(11).