期刊文献+

取水泵房超大矩形沉井布置方案设计

Design of Layout Scheme for Super-Large Rectangular Open Caisson in Water Intake Pump House
在线阅读 下载PDF
导出
摘要 为提高水资源的利用效率,城市供水系统通常采用集中取水方式,使取水泵房平面尺寸、埋置深度显著增大。文章结合工程实例,综合考虑工艺要求、地形条件、地质特征、施工方法、结构受力等因素,对取水泵房不同围护方案进行比较,最终选定沉井布置方案,并重点介绍了超大矩形沉井布置要点,以期为类似工程提供参考。 In order to improve the utilization efficiency of water resources,the urban water supply system usually adopts the centralized water intake mode,which significantly increases the plane size and buried depth of the water intake pump house.Combined with the engineering example,this paper comprehensively considers the process requirements,topographic conditions,geological characteristics,construction methods,structural force and other factors,compares different retaining schemes for the water intake pump house,and finally selects the open caisson layout scheme.It focuses on the layout points of the super-large rectangular open caisson,in order to provide reference for similar engineering.
作者 郭启金 GUO Qijin(Shanghai Municipal Engineering Design Institute(Group)Co.,Ltd.,Shanghai 200092,China)
出处 《工程技术研究》 2025年第15期1-4,共4页 Engineering and Technological Research
关键词 取水泵房 超大矩形沉井 基坑围护方案 沉井布置方案 water intake pump house super-large rectangular open caisson foundation pit retaining scheme open caisson layout scheme