期刊文献+

柴油加氢裂化装置加热炉管道振动原因分析及改造

Vibration Analysis and Modification of Heating Furnace Pipeline of Diesel Hydrocracking Unit
在线阅读 下载PDF
导出
摘要 以某石化公司3.5 Mt/a柴油加氢裂化装置分馏塔底加热炉为例,对加热炉出口管道振动原因进行分析,制定改造方案。通过在加热炉出口管道增设阻尼器,有效降低管道振动值,并对加热炉整体管道布局进行改造,合理改变管道介质流向,降低分支管道流通阻力,从而彻底解决管道振动问题。 Taking the distillation tower bottom heating furnace of a 3.5 Mt/a diesel hydrocracking unit in a petrochemical company as an example,this paper analyzes the causes of pipeline vibration at the outlet of the heating furnace and develops a renovation plan.By adding dampers to the outlet pipeline of the heating furnace,the vibration value of the pipeline can be effectively reduced,and the overall pipeline layout of the heating furnace can be modifed to reasonably change the flow direction of the pipeline medium and reduce the flow resistance of branch pipelines,thus completely solving the problem of pipeline vibration.
作者 于洋洋 А.Б.Невзорова 刘冬 葛依明 雷东海 宋吉航 赵伟 YU Yangyang;ALLA Neuzorava;LIU Dong;GE Yiming;LEI Donghai;SONG Jihang;ZHAO Wei(Zhejiang Petrochemical Co.,Ltd.,Zhoushan 316200,Zhejiang,China;Sukhoi State Technical University of Gomel,Gomel 246019,Gomel,Belarus)
出处 《四川化工》 2025年第5期36-39,共4页 Sichuan Chemical Industry
关键词 柴油加氢 加热炉 振动 原因分析 阻尼器 管道布局 改造 diesel hydrogenation heating furnace vibration cause analysis damper pipeline layout renovation
  • 相关文献

参考文献10

二级参考文献26

共引文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部