摘要
为探讨影响广州地区村落巷道夏季室外热舒适的关键形态参数,以及形态参数对热舒适的影响规律,对广州常见的“梳式”布局村落黄屋村进行了实地调研、热环境实测、巷道形态参数模型的微气候模拟及热舒适指标和形态要素的关联分析。得出以下主要结论:1)通过归一互化信息(NMI)的计算,确定了天空角系数(SVF)是对村落巷道热舒适贡献度最大的形态参数指标;2)村落巷道SVF和高宽比(H/W)之间在H/W小于2时存在明显的负相关;3)普通巷道中的生理等效温度(PET)会随着SVF的增加而降低,但东西(E-W)朝向巷道降低速率最慢;4)确定了遮阳设施对巷道热舒适的提升能力,并指出了不同宽度的遮阳设施对村落巷道PET的具体影响,并给出了遮阳设施的最佳宽度为1 m。以上结论可为广州地区村落规划设计提供必要的导引。
To examine the morphological parameters influencing outdoor thermal comfort during the summer in the alleys of villages in Guangzhou,as well as to assess the influence of these parameters on thermal comfort,the research involved conducting field studies in Huangwu village,a representative example of the“comb-lie”layout commonly found in Guangzhou,thermal environment measurements,and microclimate simulations of the morphological parameter model of the alleys.The analysis of the correlation between thermal comfort indicators and morphological elements yielded the following principal conclusions:1)The Sky View Factor(SVF)emerged as the most influential morphological parameter for enhancing thermal comfort in village alleys,as determined by the Normalized Mutual Information(NMI)method;2)A significant negative correlation was observed between the SVF and the height-to-width ratio(H/W)of the village alley when the H/W was less than 2;3)The Physiologically Equivalent Temperature(PET)in typical alleys decreased with an increase in the SVF,with the slowest rate of decrease occurring in east-west(E-W)oriented alleys;4)The ability of shading facilities to enhance thermal comfort in alleys was determined,and the specific effect of different widths of shading facilities on PET in village alleys was noted.It was determined that the optimal width for shading facilities is 1 meter.Based on the above conclusions,necessary guidance can be provided for the planning and design of villages in Guangzhou.
作者
秦士强
孟庆林(指导)
李琼
QIN Shiqiang;MENG Qinglin;LI Qiong(State Key Laboratory of Subtropical Building Science,School of Architecture,South China University of Technology,Guangzhou 510641,China)
出处
《建筑节能(中英文)》
2025年第10期63-71,共9页
Building Energy Efficiency
基金
华南理工大学中央高校基本科研业务费专项资金“粤港澳大湾区城市极端气候灾害机理辨识与防控基础研究”(2024ZYGXZR003)
国家自然科学基金资助项目“湿热地区海岛微气候调节与设计基础研究”(52178076)
广东省国际科技合作项目“长时间尺度下绿地对湿热地区城市局地气候和建筑能耗的影响研究”(2023A0505050125)
亚热带建筑与城市科学全国重点实验室自主课题“湿热地区城市街区环境高温热浪冲击表征与防热设计基础研究”(2023ZB03)。
关键词
广州地区
村落巷道
微气候实测
参数化模型
热环境模拟
巷道形态参数
Guangzhou area
village alley
microclimate measurement
parametric modeling
thermal environment simulation
alley morphology parameters