摘要 国内某核电机组核级反应堆电缆组件为俄供系统,电缆及连接器组件在现场进行操作时,容易因限位连帽过度移动而造成限位钢珠脱落丢失,存在异物掉入堆芯的风险。针对该问题设计了一款国产化电缆组件,但是在对其进行鉴定试验时电缆组件部分参数发生了异常。本文介绍了国产化核级反应堆电缆组件的结构及实验内容,并对电缆组件在鉴定试验时出现的异常进行了原因分析和故障定位。 The cable components of the nuclear-grade reactor of the Nuclear Power Plant is a Russian supply system,and when the cable and connector components are operated in the field,it is easy to cause the limit steel ball to fall off and lose due to excessive movement of the limit hood,and there is a risk that foreign objects will fall into the core of the reactor.A domestic cable components was designed for this problem,but some parameters of the cable components were abnormal during the identification test.This paper introduces the structure and experimental content of the cable components of the domestic nuclear reactor,and analyzes the cause analysis and fault location of the abnormal occurrence of the cable components during the identification test.
作者 张锦 ZHANG Jin(Shanghai Nuclear Power Co.,Ltd.,Shanghai 200233,China)
出处 《流体测量与控制》 2025年第3期98-100,共3页 Fluid Measurement & Control
关键词 核级反应堆电缆组件 鉴定试验 故障分析 故障定位 cable components of the nuclear-grade reactor identification test fault analysis fault location
  • 相关文献

参考文献8

二级参考文献68

  • 1蔡建羡,阮晓刚,甘家飞.两轮自平衡机器人系统建模与模糊自整定PID控制[J].北京工业大学学报,2009,35(12):1603-1607. 被引量:20
  • 2邹树梁.世界核电发展的历史、现状与新趋势[J].南华大学学报(社会科学版),2005,6(6):38-42. 被引量:11
  • 3王福志,姜松奕,郑红,刘晓光.核电站用1E级电缆结构设计及有关试验的探讨[J].电线电缆,2006(6):14-18. 被引量:9
  • 4刘明伟.电压采样与电流采样法的实例分析比较[A].全国第6次电力电缆运行经验交流会论文集[C].广州,2000.
  • 5Martin Buar. Cable Testing and Cable Fault Location [M].Austria, 1995.
  • 6Potivejkul S. Design of a Low Voltage Cable Fault Detector[A].IEEE Power Engineering Society Winter Meeting[C], 2000.
  • 7Kazuo Amano. Fault Location System for Power Cable Using Global Positioning System[J]. Fujikura Technical Review, 2002(1):73-76.
  • 8RCC-E-2005压水堆核岛电气设备设计和建造规则[s].AFCEN:[s.n.],2005.
  • 9EDF CST74C06800-2004 Electrical cables for nuclear power plants[S]. EDF..[s. n. ],2004.
  • 10IEC 60216-1-2001 Electrical insulation materials properties of thermal endurance--part 1.. ageing procedures and evaluation of test results[S]. IEC: [s. n. ] ,2001.

共引文献116

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部