期刊文献+

锌盐缓蚀剂在循环冷却水中的应用研究

Research on the Application of Zinc Salt Corrosion Inhibitors in Circulating Cooling Water
在线阅读 下载PDF
导出
摘要 通过锌盐缓蚀剂SPC-302与阻垢分散剂SPC-5501的质量浓度提升试验,探究药剂质量浓度、pH、总碱度及泄漏情况对总锌质量浓度的影响。试验结果表明:SPC-302质量浓度应低于15 mg/L,SPC-5501与SPC-302添加比例应在12∶1以上,pH升高会加剧锌的沉降,SPC-5501可提升锌的稳定性。 The spiking experiments with zinc salt corrosion inhibitor(SPC-302)and scale-inhibiting dispersant(SPC-5501)were conducted to investigate the effects of chemical dosage,pH,total alkalinity,and leakage on total zinc stability.The results demonstrated that:The SPC-302 concentration should be maintained≤15 mg/L,the ratio of SPC-5501 to SPC-302 needs to exceed 12∶1,elevated pH accelerates zinc sedimentation,while the scale-inhibiting dispersant enhances zinc stability.This study provides theoretical support for the efficient application of zinc salt corrosion inhibitors.
作者 沈凤 Shen Feng(Shanghai Miaoqing Water Treatment Co.,Ltd.,Shanghai 200540)
出处 《石油化工技术与经济》 2025年第3期35-40,共6页 Technology & Economics in Petrochemicals
关键词 循环水 锌盐缓蚀剂 阻垢分散剂 稳定性 circulating water zinc salt corrosion inhibitor scale/dispersant inhibitor stability